Fourier transform infrared photoacoustic multicomponent gas spectroscopy with optical cantilever detection
Christian Bernd Hirschmann1, Juho Uotila, Satu Ojala
1Mass and Heat Transfer Process Laboratory, Department of Process and Environmental Engineering, FI-90014 University of Oulu, Finland. Christian.Hirschmann@vtt.fi
Abstract:
The sensitivity of photoacoustic spectroscopy was improved with the invention of optical cantilever detection (PAS-OCD). However, the ability of present PAS-OCD devices to carry out multicomponent detection is poor. To overcome this, a Fourier transform infrared photoacoustic spectrometer with optical cantilever detection (FT-IR-PAS-OCD) prototype was assembled. In this article, the first evaluation and performance tests of the prototype are described. Selectivity, sensitivity, and the linearity of the signal response are evaluated. The linear response was studied for methane and carbon dioxide and confirmed in the whole analyzed concentration range from 500 to 3500 ppm and from 2500 to 17500 ppm, respectively. The calculated signal-to-noise ratio (SNR) and limit of detection were 2027 and 0.5 ppm for methane and 1362 and 4 ppm for carbon dioxide, with a measurement time of 100 seconds. Selectivity was studied with a multicomponent gas mixture of propene, methane, carbon dioxide, and methylmercaptane. The results indicate that a quantitative analysis of all components in the mixture is possible using the FT-IR-PAS-OCD.
Related Concept Videos
IR Spectrometers
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to the...
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...