A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
A comparison of response time to desaturation between tracheal oximetry and peripheral oximetry
1Department of Anesthesiology, NO. 1 People's Hospital of Yibin, Yibin, Sichuan, China.
Objective:
Trachea is an alternative site for pulse oxygen saturation monitoring. The response time of the oximetry probe has been reported more rapid when placed in central than in peripheral. The purpose of this study is to compare the performance of the oximetry probes placed in trachea and peripheral site during rapid desaturation.
Methods:
Endotracheal tubes with an oximetry sensor were intubated in ten anesthesia dogs. Both the oxygen saturation signals from trachea (S(t)O(2)) and tail (S(p)O(2)) were shown on the same monitoring screen. The mechanical ventilation was disconnected to produce a rapid desaturation when both S(t)O(2) and S(p)O(2) were 100%, and the mechanical ventilation was reconnected when S(p)O(2) decreased to 80%. The time of S(t)O(2) and S(p)O(2) dropped to 95, 90, 85, and 80% was recorded, respectively during the mechanical ventilation disconnection, and the arterial blood was sampled for arterial oxygen saturation (S(a)O(2)) measurement simultaneously. The levels of measurement agreement between two oximetry readings (S(p)O(2), S(t)O(2)) and S(a)O(2) were analyzed, respectively with the Bland and Altman method.
Results:
The mean response time of S(t)O(2) was significantly shorter than S(p)O(2) when both of them decreased from 100 to 80% (172.6+/-68.9 vs 220.7+/-72.3 s) during rapid desaturation. The 95% confidence interval for absolute difference between S(p)O(2) and S(a)O(2) was 4.12+/-6.47%, and between S(t)O(2) and S(a)O(2) was 3.33-3.46%.
Conclusions:
Oxymetry placed in trachea provides a better monitoring for detecting rapid desaturation than in peripheral.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration can...