Potential errors in pulse oximetry. III: Effects of interferences, dyes, dyshaemoglobins and other pigments
A C Ralston1, R K Webb, W B Runciman
1Department of Anaesthesia and Intensaive Care, Royal Adelaide Hospital, North Terrace, Australia.
Abstract:
Electrosurgery, patient motion and some types of lighting can cause errors in saturation readout; it is recommended that probes should be shielded from ambient lighting. Intravenous dyes can introduce gross but transient errors, which may also be present in in vitro measurements. Carboxyhaemoglobin causes overestimation of fractional saturation by an amount less than, but possibly close to, the percent of carboxyhaemoglobin present. Methaemoglobin causes the pulse oximeter readout to tend towards 85%. Fetal haemoglobin and bilirubin introduce no significant error, although they may interfere with in vitro measurements. Skin pigmentation can result in a slight decrease in accuracy. Nail polish may cause up to 6% underestimation of saturation; it is recommended that probes should be mounted sideways on fingers with nail polish or long nails. Adhesive tape or a vinyl glove across the probe has no demonstrable effect on accuracy. A blood sample should be analysed by a multiwavelength in vitro oximeter when an erroneous pulse oximeter reading is suspected, although errors may be introduced in the in vitro reading by fetal haemoglobin, bilirubin and intravenous dyes.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
04:44Near-Infrared Spectroscopy During Reactive Hyperemia for the Assessment of Lower Limb Vascular Function
Published on: March 22, 2024
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Errors occurring during blood pressure monitoring
Several factors...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...