Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Overview of Electron Microscopy01:25

Overview of Electron Microscopy

The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
Transmission Electron Microscopy01:15

Transmission Electron Microscopy

In 1931, physicist Ernst Ruska—building on the idea that magnetic fields can direct an electron beam just as lenses can direct a beam of light in an optical microscope—developed the first prototype of the electron microscope. This development led to the development of the field of electron microscopy. In the transmission electron microscope (TEM), electrons are produced by a hot tungsten element and accelerated by a potential difference in an electron gun, which gives them up to 400 keV in...
Cryo-electron Microscopy01:28

Cryo-electron Microscopy

Conventional electron microscopy (EM) involves dehydration, fixation, and staining of biological samples, which distorts the native state of biological molecules and results in several artifacts. Also, the high-energy electron beam damages the sample and makes it difficult to obtain high-resolution images. These issues can be addressed using cryo-EM, which uses frozen samples and gentler electron beams. The technique was developed by Jacques Dubochet, Joachim Frank, and Richard Henderson, for...
Overview of Microscopy Techniques01:22

Overview of Microscopy Techniques

The early pioneers of microscopy opened a window into the invisible world of microorganisms. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes that leveraged nonvisible light, such as fluorescence microscopy that uses an ultraviolet light source and electron microscopy that uses short-wavelength electron beams. These advances significantly improved magnification, image resolution, and contrast. By comparison, the...
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Preparation of Samples for Electron Microscopy01:20

Preparation of Samples for Electron Microscopy

To be visualized by an electron microscope, either transmission or scanning, biological samples need to be fixed (stabilized) so the electron beam does not destroy them and dried thoroughly (desiccated/dehydrated) so the vacuum does not affect them. Fixation needs to be done as quickly as possible because the sample properties will start changing as soon as it is removed from its natural environment. For example, in a tissue sample, the oxygen levels begin decreasing, causing an altered...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Human papillomavirus 16 and p16 positive nasal cutaneous squamous cell carcinoma in immunocompetent men in their twenties.

The Journal of laryngology and otology·2019
Same author

Short-term changes observed in multiparametric liver MRI following therapy with direct-acting antivirals in chronic hepatitis C virus patients.

European radiology·2018
Same author

Current and Future Magnetic Resonance Technologies for Assessing Liver Disease in Clinical and Experimental Medicine.

Digestive diseases (Basel, Switzerland)·2017
Same author

Buccal corridor airway adjunct for intermaxillary fixation.

The British journal of oral & maxillofacial surgery·2015
Same author

Are junior doctors in today's NHS competent in managing ophthalmic cases in the emergency department?

Eye (London, England)·2015
Same author

Displacement of mandibular fractures: is there a correlation with sensory loss and recovery?

International journal of oral and maxillofacial surgery·2014
Same journal

Neuroimaging in schizophrenia: From group-average abnormalities to individualised circuit models.

Science progress·2026
Same journal

Clinical and mechanistic effects of GLP-1 receptor agonists in hidradenitis suppurativa and comorbidities.

Science progress·2026
Same journal

Association between serum albumin-to-globulin ratio and diabetic retinopathy: A cross-sectional study based on the 2001-2020 NHANES database.

Science progress·2026
Same journal

Prognostic value of the triglyceride-glucose index combined with glycemic variability for all-cause mortality in patients with sepsis: A retrospective cohort study.

Science progress·2026
Same journal

Asynchronous federated learning with partial weights aggregation for energy consumption forecasting.

Science progress·2026
Same journal

Prediction of laser welding molten pool light intensity distribution based on an artificial neural network.

Science progress·2026
See all related articles

Related Experiment Video

Updated: Jun 15, 2026

A Method for Obtaining Serial Ultrathin Sections of Microorganisms in Transmission Electron Microscopy
09:46

A Method for Obtaining Serial Ultrathin Sections of Microorganisms in Transmission Electron Microscopy

Published on: January 17, 2018

Electron microscopy

R A SCOTT

    Science Progress
    |March 19, 2010
    PubMed
    Summary

    No abstract available in PubMed .

    Keywords:
    ELECTRON MICROSCOPY

    More Related Videos

    Mitochondria and Endoplasmic Reticulum Imaging by Correlative Light and Volume Electron Microscopy
    09:21

    Mitochondria and Endoplasmic Reticulum Imaging by Correlative Light and Volume Electron Microscopy

    Published on: July 20, 2019

    Miniaturized Sample Preparation for Transmission Electron Microscopy
    09:04

    Miniaturized Sample Preparation for Transmission Electron Microscopy

    Published on: July 27, 2018

    Related Experiment Videos

    Last Updated: Jun 15, 2026

    A Method for Obtaining Serial Ultrathin Sections of Microorganisms in Transmission Electron Microscopy
    09:46

    A Method for Obtaining Serial Ultrathin Sections of Microorganisms in Transmission Electron Microscopy

    Published on: January 17, 2018

    Mitochondria and Endoplasmic Reticulum Imaging by Correlative Light and Volume Electron Microscopy
    09:21

    Mitochondria and Endoplasmic Reticulum Imaging by Correlative Light and Volume Electron Microscopy

    Published on: July 20, 2019

    Miniaturized Sample Preparation for Transmission Electron Microscopy
    09:04

    Miniaturized Sample Preparation for Transmission Electron Microscopy

    Published on: July 27, 2018