Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
Gas Chromatography: Overview of Detectors01:13

Gas Chromatography: Overview of Detectors

Detectors in gas chromatography (GC) help identify and quantify the components of a mixture by translating chemical properties into measurable signals, which are displayed on a chromatogram. Detectors can be categorized into two main types: destructive and non-destructive.
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
IR Spectrometers01:25

IR Spectrometers

There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

The aging of glass surfaces.

Journal of the Optical Society of America·2010
Same author

Improved infra-red polarizer.

Journal of the Optical Society of America·2010
Same author

Optical scattering by dielectric powders of uniform particle size.

Journal of the Optical Society of America·2010
Same author

Rocket instrument for far-UV spectrophotometry of faint astronomical objects.

Applied optics·2010
Same author

Construction, calibration, and application of a compact spectrophotometer for EUV (300-2500-A) plasma diagnostics.

Applied optics·2010
Same author

Comprehensive analysis of gratings for ultraviolet space instrumentation.

Applied optics·2010
Same journal

Response curves for types of vision according to the Müller theory.

Journal of the Optical Society of America·2010
Same journal

Reading equipment for partially blind people.

Journal of the Optical Society of America·2010
Same journal

Effects of anoxia, oxygen, and increased intrapulmonary pressure on dark adaptation.

Journal of the Optical Society of America·2010
Same journal

Investigations on the site of origin of blackout in man.

Journal of the Optical Society of America·2010
Same journal

The ultraviolet absorption spectra and other physical data for cardiolipin, a new phospholipid, and lecithin isolated from beef heart.

Journal of the Optical Society of America·2010
Same journal

The effect of colored lenses upon color discrimination.

Journal of the Optical Society of America·2010
See all related articles

Related Experiment Video

Updated: Jun 15, 2026

Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
10:22

Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements

Published on: September 7, 2019

Selective infrared gas analyzers

W G FASTIE, A H PFUND

    Journal of the Optical Society of America
    |March 19, 2010
    PubMed
    Summary

    No abstract available in PubMed .

    Keywords:
    GAS ANALYZER/infraredINFRA-RED/gas analyzer

    More Related Videos

    Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
    10:42

    Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing

    Published on: March 22, 2019

    Automated, High-resolution Mobile Collection System for the Nitrogen Isotopic Analysis of NOx
    07:14

    Automated, High-resolution Mobile Collection System for the Nitrogen Isotopic Analysis of NOx

    Published on: December 20, 2016

    Related Experiment Videos

    Last Updated: Jun 15, 2026

    Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
    10:22

    Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements

    Published on: September 7, 2019

    Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
    10:42

    Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing

    Published on: March 22, 2019

    Automated, High-resolution Mobile Collection System for the Nitrogen Isotopic Analysis of NOx
    07:14

    Automated, High-resolution Mobile Collection System for the Nitrogen Isotopic Analysis of NOx

    Published on: December 20, 2016