Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Atomic Absorption Spectroscopy: Atomization Methods01:25

Atomic Absorption Spectroscopy: Atomization Methods

Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the aerosol...
Atomic Absorption Spectroscopy: Instrumentation01:22

Atomic Absorption Spectroscopy: Instrumentation

An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Emission Spectroscopy: Instrumentation01:22

Atomic Emission Spectroscopy: Instrumentation

The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers.  Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Fluorescence Spectroscopy01:29

Atomic Fluorescence Spectroscopy

Atomic fluorescence spectroscopy (AFS) is an analytical technique that involves the electronic transitions of atoms in a flame, furnace, or plasma being excited by electromagnetic (EM) radiation. When these atoms absorb energy, they become excited and subsequently release energy as they return to their original state. This emitted light, or "fluorescence," is observed at a right angle to the incident beam. Both absorption and emission processes transpire at distinct wavelengths, which are...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle01:19

Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle

Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Preliminary report of the use of sulfadiazine bentonite solution in the treatment of external otitis.

Military surgeon·2010
Same author

Fatigue in B-29 crewmen.

Bulletin of the U.S. Army Medical Department. United States. Army. Medical Department·2010
Same author

A compression fracture of the spine.

Bulletin of the U.S. Army Medical Department. United States. Army. Medical Department·2010
Same author

Letter: Atrial pacing during angiography--II.

The American journal of cardiology·1975
Same author

Internal mammary artery bypass graft--long-term patency rate and follow-up.

The Annals of thoracic surgery·1974
Same author

Correlation between cine-coronary arteriography and small Q-wave.

Virginia medical monthly·1974
Same journal

INFLUENCE OF natural waters on the effectiveness of DDT as a mosquito larvicide.

Bulletin of the U.S. Army Medical Department. United States. Army. Medical Department·2010
Same journal

Tissue carrier. 731 aging.

Bulletin of the U.S. Army Medical Department. United States. Army. Medical Department·2010
Same journal

Modification of a standard chlorine comparator for field ortho-tolidine-arsenite (OTA) tests.

Bulletin of the U.S. Army Medical Department. United States. Army. Medical Department·2010
Same journal

A micro method for determination of hemoglobin.

Bulletin of the U.S. Army Medical Department. United States. Army. Medical Department·2010
Same journal

The administration of fixed hospital laboratories.

Bulletin of the U.S. Army Medical Department. United States. Army. Medical Department·2010
Same journal

An unusual case of mumps without parotitis.

Bulletin of the U.S. Army Medical Department. United States. Army. Medical Department·2010
See all related articles

Related Experiment Video

Updated: Jun 14, 2026

Enhancement Method of Surface Acoustic Wave-Atomizer Efficiency for Olfactory Display
08:06

Enhancement Method of Surface Acoustic Wave-Atomizer Efficiency for Olfactory Display

Published on: November 14, 2018

Compressed air atomizer

H A ZIMMERMAN

    Bulletin of the U.S. Army Medical Department. United States. Army. Medical Department
    |March 19, 2010
    PubMed
    Summary

    No abstract available in PubMed .

    Keywords:
    VAPORIZERS

    More Related Videos

    Use of Capillary Aerosol Generator in Continuous Production of Controlled Aerosol for Non-Clinical Studies
    08:33

    Use of Capillary Aerosol Generator in Continuous Production of Controlled Aerosol for Non-Clinical Studies

    Published on: April 12, 2022

    Related Experiment Videos

    Last Updated: Jun 14, 2026

    Enhancement Method of Surface Acoustic Wave-Atomizer Efficiency for Olfactory Display
    08:06

    Enhancement Method of Surface Acoustic Wave-Atomizer Efficiency for Olfactory Display

    Published on: November 14, 2018

    Use of Capillary Aerosol Generator in Continuous Production of Controlled Aerosol for Non-Clinical Studies
    08:33

    Use of Capillary Aerosol Generator in Continuous Production of Controlled Aerosol for Non-Clinical Studies

    Published on: April 12, 2022