Related Experiment Videos
Recognition of pacemaker lead infection by transoesophageal echocardiography
G Van Camp1, J L Vandenbossche
1Department of Cardiology, Hôpital Universitaire Saint-Pierre, Brussels, Belgium.
British Heart Journal
|April 1, 1991
Abstract:
Transoesophageal echocardiography identified a pacemaker lead infection in a patient in whom transthoracic echocardiography was negative and there were no specific signs of skin inflammation over the pulse generator.