Related Experiment Video
Updated: Jun 14, 2026

A Novel Rescue Technique for Difficult Intubation and Difficult Ventilation
Published on: January 17, 2011
Swallowing dysfunction in nonneurologic critically ill patients who require percutaneous dilatational tracheostomy
Carlos M Romero1, Andrés Marambio, Jorge Larrondo
1Unidad de Pacientes Críticos, Departamento de Medicina, Hospital Clínico Universidad de Chile, Facultad de Medicina Universidad de Chile, Santos Dumont 999, Independencia, Santiago Norte, Chile. caromero@redclinicauchile.cl
Background:
The aim of this study was to determine the incidence of swallowing dysfunction in nonneurologic critically ill patients who require percutaneous dilatational tracheostomy (PDT) for prolonged mechanical ventilation (MV) and to compare the duration of the cannulation period and length of stay in the critical care unit (CCU) in patients with and without swallowing dysfunction.
Methods:
A total of 40 consecutive patients without neurologic disorders who require PDT for prolonged MV were included. Previous to the tracheostomy decannulation process, an otolaryngologist performed a fiberoptic endoscopic evaluation of swallowing (FEES). We used analysis of variance for the analysis; the results are presented as mean values +/- SD.
Results:
Mean age was 62 +/- 15 years. Acute Physiology and Chronic Health Evaluation II and Sequential Organ Failure Assessment scores were 21 +/- 2 and 9 +/- 1, respectively. Time of MV previous to PDT was 20 +/- 11 days, total MV duration was 38 +/- 16 days, and CCU stay was 63 +/- 27 days. The incidence of swallowing dysfunction in this group of patients was 38% (15/40). No difference was found in the age or time period of MV previous to PDT between groups. The time period between FEES to tracheostomy decannulation process was 19 +/- 11 days in patients with swallowing dysfunction vs 2 +/- 4 days in those patients without dysfunction (P < .001). Patients who developed swallowing dysfunction stayed longer in the CCU (69 +/- 23 vs 47 +/- 19 days, P < .01).
Conclusions:
Nearly 40% of nonneurologic critically ill patients requiring PDT for prolonged MV presented swallowing dysfunction and experienced a significant delay in their tracheostomy decannulation process.
Related Concept Videos
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...