Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration
Published on: February 23, 2017
Least-squares calibration method for fringe projection profilometry considering camera lens distortion
Lei Huang1, Patrick S K Chua, A Asundi
1School of Mechanical and Aerospace Engineering, Nanyang Technological University, Nanyang Avenue, 639798, Singapore. huanglei0114@gmail.com
Abstract:
By using the least-squares fitting approach, the calibration procedure for fringe projection profilometry becomes more flexible and easier, since neither the measurement of system geometric parameters nor precise control of plane moving is required. With consideration of camera lens distortion, we propose a modified least-squares calibration method for fringe projection profilometry. In this method, camera lens distortion is involved in the mathematical description of the system for least-squares fitting to reduce its influence. Both simulation and experimental results are shown to verify the validity and ease of use of this modified calibration method.
More Related Videos
11:34High-resolution, High-speed, Three-dimensional Video Imaging with Digital Fringe Projection Techniques
Published on: December 3, 2013
11:57Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy (iPALM)
Published on: December 1, 2016
Related Concept Videos
Influence of Earth's Curvature and Atmospheric Refraction on Leveling
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...