Related Experiment Video
Updated: Aug 11, 2026

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
How reliable are short-term measurements of oxygen uptake in polytraumatized and long-term ventilated patients?
W Behrendt1, M Surmann, J Raumanns
1Clinic of Anaesthesiology, Medical Faculty, University of Technology, Aachen, FRG.
Abstract:
O2-uptake was measured continuously in 18 polytraumatized and 21 long-term ventilated patients. All patients were on assisted ventilation with sufficient sedation and analgesia. O2-uptake was measured every minute, the values were recorded over 24 h and the mean O2-uptake/min was calculated. At the same time, the O2-uptake of the last 15 min of every hour was measured separately (e.g. 7.45-8.00, 8.45-9.00, etc.). The mean O2-uptake/min measured continuously was compared and correlated with the mean O2-uptake per day, calculated on the basis of each of the short-term measurements. There were only slight differences between the mean values of the two procedures: In the group of long-term ventilated patients the mean O2-uptake was found to be 364 ml/min in continuous measurements and 363 ml/min in short-term measurements. This O2-uptake corresponded to an energy expenditure of 2360 kcal/day. The mean correlation coefficient was 0.89 (range: 0.79-0.96). If O2-uptake was measured over 2 periods of 15 min each, e.g. in the late morning and in the afternoon, the mean correlation coefficient improved to 0.94 and the standard deviation was reduced. Comparable results were obtained in the group of polytraumatized patients. This study shows that under certain preconditions short-term measurements of O2-uptake of 2 x 15 min allow sufficiently reliable predictions of the daily O2-uptake and energy expenditure in severely traumatized or critically ill patients.
More Related Videos
07:48Noninvasive and Invasive Renal Hypoxia Monitoring in a Porcine Model of Hemorrhagic Shock
Published on: October 28, 2022
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration can...
Acute Respiratory Failure-IV
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...