Aerosol chemical composition over Istanbul

C Theodosi1, U Im, A Bougiatioti

  • 1Environmental Chemical Processes Laboratory, Department of Chemistry, University of Crete, P.O. Box 2208, 71003 Heraklion, Greece.

Related Concept Videos

The Colloidal State01:29

The Colloidal State

The formation of a colloidal system is exemplified by an aqueous solution containing Cl− ions is introduced to another containing Ag+ ions, resulting in the precipitation of solid AgCl as extremely tiny crystals. Instead of settling out as a filterable precipitate, these crystals remain suspended in the liquid, showcasing a colloidal system.A colloidal system involves colloidal particles within the approximate range of 1 to 1000 nm in at least one dimension, dispersed in a medium called the...
Atomic Absorption Spectroscopy: Atomization Methods01:25

Atomic Absorption Spectroscopy: Atomization Methods

Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the aerosol...
Atomic Emission Spectroscopy: Instrumentation01:22

Atomic Emission Spectroscopy: Instrumentation

The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers.  Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
Chemical Ionization (CI) Mass Spectrometry01:21

Chemical Ionization (CI) Mass Spectrometry

The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
Effects of Chemicals: Overview01:27

Effects of Chemicals: Overview

Drugs, encompassing various chemical compounds from natural sources, lab synthesis, or genetic engineering, elicit different biological responses in living organisms. Some of these responses are desirable or therapeutic, while others are undesirable. The primary goal of administering a drug is to achieve a therapeutic effect, that is, to address a specific disease or health condition. Any concurrent effects outside of this therapeutic outcome are considered undesirable. These undesirable...
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...