Related Experiment Video
Updated: Jun 14, 2026

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
Published on: June 21, 2024
Bayesian k -space-time reconstruction of MR spectroscopic imaging for enhanced resolution
John Kornak1, Karl Young, Brian J Soher
1Department of Radiology and Biomedical Imaging and the Department of Epidemiology and Biostatistics, University of California, SanFrancisco, San Francisco, CA 94107, USA. john.kornak@ucsf.edu
None:
A k-space-time Bayesian statistical reconstruction method (K-Bayes) is proposed for the reconstruction of metabolite images of the brain from proton (1H) magnetic resonance (MR) spectroscopic imaging (MRSI) data. K-Bayes performs full spectral fitting of the data while incorporating structural (anatomical) spatial information through the prior distribution. K-Bayes provides increased spatial resolution over conventional discrete Fourier transform (DFT) based methods by incorporating structural information from higher resolution coregistered and segmented structural MR images. The structural information is incorporated via a Markov random field (MRF) model that allows for differential levels of expected smoothness in metabolite levels within homogeneous tissue regions and across tissue boundaries. By further combining the structural prior model with a k -space-time MRSI signal and noise model (for a specific set of metabolites and based on knowledge from prior spectral simulations of metabolite signals), the impact of artifacts generated by low-resolution sampling is also reduced. The posterior-mode estimates are used to define the metabolite map reconstructions, obtained via a generalized expectation-maximization algorithm. K-Bayes was tested using simulated and real MRSI datasets consisting of sets of k-space-time-series (the recorded free induction decays). The results demonstrated that K-Bayes provided qualitative and quantitative improvement over DFT methods.
Related Concept Videos
NMR Spectrometers: Resolution and Error Correction
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Super-resolution Fluorescence Microscopy
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
¹H NMR of Labile Protons: Temporal Resolution
The –OH proton in alcohols typically appears in the range of δ 2 to 5 ppm but can vary depending on the specific...
High-Resolution Mass Spectrometry (HRMS)
