Correlation of positron emission tomography with fine needle aspiration biopsies in head and neck malignancy
Vincenzo Ciocca1, Matthew C Miller, William M Keane
1Department of Pathology, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania, USA. cioccav@mlhs.org
Objective:
To investigate whether a correlation between fine needle aspiration cytology and positron emission tomography (PET) exists in the preoperative screening, staging and diagnosis of head and neck cancer.
Study Design:
We retrospectively correlated fine needle aspiration biopsy (FNAB) and PET scan in patients with head and neck lesions.
Results:
There were 92 FNABs with corresponding PET scan in 83 patients. Mean standard uptake value (SUV) for benign lymph nodes was 5.05 (SD, 5.79), and 13.56 (SD, 6.38) and 16.99 (SD, 19.04) for squamous carcinoma and other malignancies, respectively. Ideal SUV cutoff value was determined to be 6.0. Of 66 malignant FNABs, 52 had an SUV > or = 6, 8 had an SUV < 6, and 6 were interpreted as "hypermetabolic." Of 26 benign FNAB (SUV was available for 17), 8 were interpreted as "hypermetabolic" and 1 as "not hypermetabolic." Of those with SUVs reported, 15 were < 6 while 2 were > or = 6.
Conclusion:
Lesions with SUV 6 are more likely to harbor malignancy, while lesions with repeatedly negative FNAB in the context of SUV > 6 should be considered for open biopsy. Further, lesions with SUV < 6 may harbor malignancy and therefore fine needle aspiration biopsy is also recommended.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET