Related Experiment Video
Updated: Jun 14, 2026

Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Flat-detector computed tomography with intravenous contrast material application in experimental aneurysms:
Tobias Struffert1, Marc Doelken, Edyta Adamek
1Department of Neuroradiology, University of Erlangen-Nuremberg, Erlangen, Germany. tobias.struffert@uk-erlangen.de
Background:
Despite limited soft tissue resolution flat-detector computed tomography (FD-CT) provides substantial superior spatial resolution in comparison with multislice computed tomography (MS-CT). This may add value in the visualization of small vascular structures if intravenous contrast application leads to substantial opacification and visibility of intracranial vessels or aneurysms.
Purpose:
To evaluate the feasibility of visualization of vascular structures by FD-CT angiography (FD-CTA) after intravenous contrast injection compared with MS-CTA and intra-arterial digital subtracted angiography (IADSA) in an animal model.
Material And Methods:
Aneurysms were created in the right common carotid artery in six New Zealand White Rabbits using the elastase technique. Imaging was performed using FD-CTA, MS-CTA (injection of 1 ml/kg body weight) and IADSA. Anonymized volume rendering reconstruction (VRT), maximum intensity projection (MIP), and multiplanar reconstruction (MPR) images were reconstructed and evaluated by two experienced reviewers for aneurysm geometry and vascular structure anatomy using standard tools of a dedicated workstation.
Results:
Aneurysms could be successfully created in all animals. Measurements of aneurysm geometry (aneurysm height, width, neck width) and vascular structures (brachiocephalic trunk, carotid artery diameter and plane) were nearly identical in all three modalities. Intra- and inter-observer correlations of the different parameters showed high r values between 0.83 and 0.99.
Conclusion:
Our results show the feasibility of FD-CTA in comparison with MS-CTA and IADSA in an animal model. Despite limited soft tissue resolution, opacification of vascular structures with sufficient contrast to the surrounding structures was possible in all animals. Vascular structures appeared better delineated in FD-CTA than in MS-CTA, probably due to the superior spatial resolution.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
06:02Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies VII: Vascular Imaging