Comprehensive gas chromatography with Time of Flight MS and large volume introduction for the detection of
J A van der Meer1, H C Trap, D Noort
1TNO Defence, Security and Safety, PO Box 45, 2280 AA Rijswijk, The Netherlands.
Abstract:
Recently, several methods have been developed to verify exposure to nerve agents. Most of these methods, such as the fluoride reactivation technique and the analysis of inhibited phosphonylated butyrylcholinesterase (BuChE), are based on mass spectrometry. The high specificity of the mass spectrometer might also imply a disadvantage, because the acquisition mass, i.e. the identity of the analyte must be known beforehand in order to direct the MS analysis in the most sensitive mode. In real cases, the identity of the nerve agent is not always known beforehand and the mass spectrometer should be operated in a scanning mode, with the consequence that sensitivity of the method will be lower. Comprehensive GC, or GC x GC, is a technique which offers enhanced separation. The implied larger selectivity of the GC separation allows mass spectrometry to be conducted in a less specific, scanning, mode. By the use of this configuration, the identity of the nerve agent does not have to be known beforehand but can be traced. In order to be able to detect lower concentrations and assess lower exposure levels, a large volume injection technique was developed allowing sample sizes up to 100 microL. The technique was tested with plasma samples that had been inhibited with various nerve agents. Subsequently, the cholinesterase-bound nerve agent was regenerated by the fluoride reactivation technique. Using the newly developed comprehensive GC-MS method it was possible to detect nerve agent at an exposure level of 1% BuChE inhibition, which is approximately 70 pg nerve agent/mL. These low exposure levels cannot be verified with a cholinesterase (ChE) activity assay. Moreover, the identity of the regenerated nerve agent was verified by the mass spectrum that was generated by the TOF mass spectrometer. This paper presents a technique able to deliver full-scan data on the analysis of nerve agents in biomedical samples at relevant exposure levels (1% BuChE inhibition). This full-scan data meets for a large part the forensic requirements that are in place for the analysis of biomedical samples in the context of alleged use of Chemical Warfare Agents.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...