Contrast material injection protocol with the dose adjusted to the body surface area for MDCT aortography
Yumi Yanaga1, Kazuo Awai, Takeshi Nakaura
1Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556, Japan.
Objective:
The objective of our study was to investigate the effect on aortic enhancement of contrast material volumes adjusted for a patient's body surface area (BSA) at CT angiography (CTA).
Subjects And Methods:
A 64-MDCT scanner was used to perform CTA of the whole aorta in 89 patients (mean age, 68.7 years) with confirmed or suspected aortoiliac disease. The patients were divided into groups: a body weight (BW) group (n = 45) and a BSA (n = 44) group. The contrast dose was 360 mg I/kg BW in the BW group and 12,753 mg I/m(2) BSA in the BSA group. Because the average BW of Japanese adults is approximately 60 kg, the contrast dose in the two protocols was identical in patients weighing 60 kg. We compared aortic enhancement achieved with the two protocols using the two-tailed Student's t test, and we used the generalized linear model to analyze the effect of patient age, sex, and BW on aortic enhancement in each protocol group.
Results:
The mean aortic enhancement in the BW and BSA groups was 324.2 and 311.7 HU, respectively; the difference was not significant (p = 0.26). In the BW group, BW had a statistically significant effect on aortic enhancement (p < 0.01), whereas neither patient age nor sex did (p = 0.08 and 0.07, respectively). In the BSA group, the age, sex, BW, and BW by sex had no statistically significant effect on aortic enhancement (p = 0.33, 023, 0.10, and 0.16, respectively).
Conclusion:
Under the BSA protocol, aortic enhancement tended to be consistent and adequate regardless of patient BW.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies VII: Vascular Imaging