Objective:
Prospectively ECG-triggered coronary CT angiography images are acquired during a window in middiastole. Additional surrounding x-ray beam on time, or padding, can be variably set, and the increased padding results in additional available phases for analysis. The purpose of this study was to assess the effect of padding duration on image interpretability and its incident effect on radiation dose.
Subjects And Methods:
We prospectively evaluated imaging of 886 patients undergoing consecutive prospectively ECG-triggered coronary CT angiographic examinations at three centers and compared the findings in patients stratified by padding duration. We assessed the effect of padding duration on image interpretability and radiation dose.
Results:
The mean patient age was 56 +/- 12 years, and 58% of the patients were men. The median heart rate was 55 beats/min (interquartile range, 50-61 beats/min). Padding duration was 0, 1-99, and 100-150 milliseconds for 268, 482, and 136 patients, respectively, with no difference in image interpretability rate between groups (per patient, 98.8%, 97.3%, and 97.1%; per artery, 99.2%, 99.2%, and 99.1%). The groups differed in median radiation dose (2.3 mSv [interquartile range, 1.5-3.2 mSv]; 3.8 mSv [interquartile range, 2.3-4.7 mSv]; 5.5 mSv [interquartile range, 3.8-6.1 mSv]; p < 0.001). Independent of patient and scan parameters, increased padding was associated with greater radiation dose (45% increase per 100-millisecond increase in padding, p < 0.001).
Conclusion:
In a large multicenter study of coronary CT angiography of patients with excellent heart rate control, the use of minimal padding was associated with a substantial reduction in radiation dose with preserved image interpretability. Use of no or reduced padding should be considered in dose-reduction strategies.
More Related Videos
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Cardiac Catheterization I: Pre-Procedure Overview
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...