Duplex scanning for arterial trauma.

M Meissner1, M Paun, K Johansen

  • 1Department of Surgery, Harborview Medical Center, Seattle, Washington 98104.

American Journal of Surgery
|May 1, 1991
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Growth and feed efficiency of Nordic Red Dairy Cattle, Holstein, and their F<sub>1</sub> crossbreeds when limiting feed energy concentration in prepubertal heifers.

Journal of dairy science·2024
Same author

An outbreak of mumps in Sweden, February-April 2004.

Euro surveillance : bulletin Europeen sur les maladies transmissibles = European communicable disease bulletin·2017
Same author

Where are we in our understanding of the association between narcolepsy and one of the 2009 adjuvanted influenza A (H1N1) vaccines?

Biologicals : journal of the International Association of Biological Standardization·2016
Same author

Opposite-side flavour tagging of <i>B</i> mesons at the LHCb experiment.

The European physical journal. C, Particles and fields·2015
Same author

Measurement of <b></b> production in <b></b> collisions at [Formula: see text].

The European physical journal. C, Particles and fields·2015
Same author

Measurement of <i>ψ</i>(2<i>S</i>) meson production in <i>pp</i> collisions at [Formula: see text].

The European physical journal. C, Particles and fields·2015
Same journal

Innovative management of Anterior Cutaneous Nerve Entrapment Syndrome (ACNES): A meta-analysis and introduction of a new robotic approach with patient-based algorithm.

American journal of surgery·2026
Same journal

Does the risk outweigh the benefit? Clot progression, recanalization & complications of anticoagulation therapy in acute pancreatitis with concomitant splanchnic vein thrombosis.

American journal of surgery·2026
Same journal

High and low body mass index and 90-day postoperative outcomes in patients with Crohn's disease undergoing abdominal surgery.

American journal of surgery·2026
Same journal

Women with firearm injuries: A multicenter mixed-methods study.

American journal of surgery·2026
Same journal

SBAS presidential address: A surgeon-scientist's journey from haptic science to digital performance metrics.

American journal of surgery·2026
Same journal

Using Dr. Google and AI to stay informed.

American journal of surgery·2026
See all related articles

Duplex sonography shows promise as a rapid, noninvasive screening tool for detecting arterial trauma. This technology can reliably identify vascular injuries in patients with trauma, aiding in early diagnosis and management.

Area of Science:

  • Vascular Surgery
  • Diagnostic Imaging
  • Trauma Care

Background:

  • Arterial trauma diagnosis often relies on invasive methods or clinical suspicion.
  • Need for a reliable, noninvasive screening tool for occult vascular injuries.
  • Duplex sonography offers potential advantages in speed, cost, and portability.

Purpose of the Study:

  • To evaluate the efficacy of duplex sonography as a screening examination for arterial trauma.
  • To assess the diagnostic accuracy of duplex sonography in identifying arterial injuries.
  • To determine the utility of duplex scanning in patients presenting with trauma.

Main Methods:

  • Retrospective analysis of 89 patients with 93 arterial injuries.
  • Duplex sonography scans performed for wound proximity, clinical indications, and postoperative assessment.

Related Experiment Videos

  • Comparison of sonographic findings with clinical outcomes and injury data.
  • Main Results:

    • Positive screening scans for wound proximity: 6.7%.
    • Positive scans for clinical indications: 68%.
    • Abnormal postoperative studies: 50%.
    • Four false-negative scans (4.3%) with no missed major injuries.
    • No false-positive studies reported.

    Conclusions:

    • Duplex sonography is a rapid, noninvasive, and inexpensive method for screening arterial trauma.
    • The technology demonstrates reliability in diagnosing and localizing arterial disruptions.
    • Duplex scanning may be valuable for identifying occult vascular injuries in trauma patients.