Perception of chassis leakage current

M Levin1

  • 1Mort Levin, Inc., Natick, Massachusetts 01760.

Related Concept Videos

Charge on a Conductor01:26

Charge on a Conductor

An interesting property of a conductor in static equilibrium is that extra charges on the conductor end up on its outer surface, regardless of where they originate. Consider a hollow metallic conductor with a uniform surface charge density. Since the conductor itself is in electrostatic equilibrium, there should not be any electric field inside the conductor. Now, assume a Gaussian surface enclosing the hollow portion. Applying Gauss's law, the inner surface of the hollow conductor will not...
Kirchoff's Rules: Application01:22

Kirchoff's Rules: Application

Kirchhoff's rules quantify the current flowing through a circuit and the voltage variations around the loop in a circuit. Applying Kirchhoff's rules generates a set of linear equations that allow us to find the unknown values in circuits. These may be currents, voltages, or resistances.
When applying Kirchhoff's first rule, the junction rule, label the current in each branch and decide its direction. If the chosen direction is wrong, it will have the correct magnitude, although the current will...
Kirchhoff's Current Law01:04

Kirchhoff's Current Law

In the realm of electrical engineering, physicist Gustav Robert Kirchhoff made a significant contribution in 1847 by introducing Kirchhoff's laws for electric circuit analysis. These laws, particularly Kirchhoff's Current Law (KCL), have become foundational principles in understanding and analyzing electrical circuits.
Kirchhoff's Current Law is based on the principle of charge conservation. It states that at any node (a point where two or more circuit elements meet) in an electrical circuit,...
Series R—L Circuit Transients01:22

Series R—L Circuit Transients

In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists of...
Three-Phase Short Circuit—Unloaded Synchronous Machine01:21

Three-Phase Short Circuit—Unloaded Synchronous Machine

Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...