Related Experiment Video
Updated: Jun 14, 2026

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
Published on: January 20, 2022
Improved quantitative analysis of mass spectrometry using quadratic equations
Joo Young Yoon1, Kyung Young Lim, Sunho Lee
1School of Computer Science and Engineering, Seoul National University, Seoul, 151-742, Korea.
A new algorithm uses quadratic equations to resolve overlapping isotopic clusters in mass spectrometry (MS) based proteomics. This method improves peptide quantification accuracy and standard deviations compared to existing tools like XPRESS.
Area of Science:
- Proteomics
- Computational Biology
- Analytical Chemistry
Background:
- Accurate peptide quantification is crucial for reliable protein quantification in mass spectrometry (MS).
- Stable isotope labeling is a popular technique for relative peptide quantification.
- Overlapping isotopic clusters pose a significant challenge in peptide quantification, particularly with small mass differences.
Purpose of the Study:
- To develop a novel algorithm for resolving overlapping isotopic clusters in peptide quantification.
- To improve the accuracy and reliability of peptide quantification in MS-based proteomics.
- To provide an alternative to existing quantification algorithms like XPRESS within the Trans-Proteomic Pipeline (TPP).
Main Methods:
- Development of a new algorithm employing quadratic equations to separate overlapping isotopic clusters.
- Application of the algorithm to mTRAQ-labeled peptides analyzed by Orbitrap mass spectrometry.
- Comparison of the new algorithm's performance against the XPRESS algorithm.
Main Results:
- The proposed algorithm demonstrated more accurate ratios and better standard deviations than XPRESS for mTRAQ-labeled peptides.
- The discrepancy between the new algorithm and XPRESS increased with higher peptide masses, especially for peptides lacking lysine.
- The algorithm effectively separates overlapping isotopic clusters, enhancing quantification accuracy.
Conclusions:
- The novel quadratic equation-based algorithm offers improved peptide quantification in MS-based proteomics.
- This method provides a more accurate alternative to XPRESS, particularly for challenging peptide samples.
- The algorithm's applicability is expected to extend to other labeling techniques like (18)O and acrylamide labeling.
More Related Videos
12:49Quantification of Site-specific Protein Lysine Acetylation and Succinylation Stoichiometry Using Data-independent Acquisition Mass Spectrometry
Published on: April 4, 2018
06:51Quantitative Analysis by Thermogravimetry-Mass Spectrum Analysis for Reactions with Evolved Gases
Published on: October 29, 2018
Related Concept Videos
Mass Analyzers: Common Types
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Analyzers: Overview
Mass Spectrometry: Overview
Mass Spectrometers
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...