Related Experiment Video
Updated: Feb 9, 2026

Coronoid-Temporalis Pedicled Flap for Orbital Floor Defect Reconstruction
Published on: December 5, 2025
[An experimental study of successful tracheal replacement using pedicled latissimus dorsi muscle flap and soft Marlex
1First Department of Surgery, Kurume University School of Medicine, Japan.
Abstract:
The present experimental study was undertaken to evaluate the efficacy of combined latissimus dorsi muscle flap and soft Marlex mesh in the reconstruction of the trachea. Thirty-one mongrel dogs underwent a two-stage operation. In the first stage operation, they were divided into four groups for implanting a different prosthesis. A silicone rod was used as the core and this was rolled with soft Marlex mesh to make a prosthesis (Group A and B: without reinforce, Group C: reinforced by wrapping stainless steel mesh, Group D: reinforced with helical stain steel wire). The latissimus dorsi muscle flap was rolled circumferentially around the prosthesis and it was left in place for a period of 4 to 6 weeks. In the second stage operation, the long pedicled muscle flap with the biologically organized prosthesis was mobilized to be guided into the cervix, and the tracheal reconstruction was done with them following circumferential tracheal resection. In result, five of six dogs of group D survived more than 6 months after the replacement without anastomotic leakage or stenosis causing inflammatory granulation. Organization with neo-vascularity of the prosthesis at the time of the tracheal reconstruction was important firstly to avoid incurring complications concerning anastomosis and secondly for long-term stability of the healing and epithelialization of the prosthesis.
Related Concept Videos
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Continuous Renal Replacement Therapy
Ecological Succession
Mesh Analysis
A fundamental concept in mesh analysis is the definition of meshes and mesh currents. A mesh is a closed...
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
Mesh Analysis for AC Circuits
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...

