[Experimental study of temperature sensor in temperature-guided radiofrequency catheter ablation]
1Department of Medical Equipment and Food, Shanghai University of Science and Technology, Shanghai 200093, China. hydbn@126.com
Abstract:
In order to optimize temperature monitoring, the mean of temperature measured by Copper-CuNi thermocouple (TC) was compared with the actual temperature. By the use of the temperature response curve of TC, the data from monitoring temperature were analyzed in regard to the depth of installation, the diameter of TC hole and the material of ablation electrode. The accuracy and real-time of TC with a depth of 3.5 mm were better than those of 2.5 mm or 3 mm, when TC was installed in the ablation electrode TC hole. However, the difference of real-time performance was not obvious. When TC was installed in different TC holes with diameter of 0.44 mm, 0.42 mm, 0.33 mm respectively, TC with the diameter of 0.33 mm TC hole was noted to be of higher accuracy and better real-time to response temperature, compared with others. In terms of material quality, the slope of platinum temperature response curve was greater than that of stainless steel, while the accuracy of sensor temperature changed inconspicuously. As a result, the monitoring device of temperature should be put to the heat source as nearly as possible. Also, platinum ablation electrode with better thermal conductivity should be chosen.
More Related Videos
06:25Cooling or Warming the Esophagus to Reduce Esophageal Injury During Left Atrial Ablation in the Treatment of Atrial Fibrillation
Published on: March 15, 2020
05:43Determination of Continuity Index Values in Atrial Fibrillation Ablation with Proactive Esophageal Cooling
Published on: April 19, 2024
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Thermosensation