Laser extraction of a trapped infected port catheter in a child using existing experience from pacemaker and ICD lead

Dirk Bastian1, Klaus Fessele, Piotr Bednarski

  • 1Division of Cardiology, Klinikum Nürnberg, Nürnberg, Germany. dirk.bastian@klinikum-nuernberg.de

Insights

A trapped Port-a-Cath (PAC) in a child with systemic infection was successfully removed using a laser technique. This innovative approach avoided the need for open-heart surgery, offering a less invasive solution for complex catheter removal.

Area of Science:

  • Cardiology
  • Pediatric Surgery
  • Medical Device Technology

Background:

  • Systemic infection necessitates the removal of implanted devices like the Port-a-Cath (PAC).
  • PAC removal can be challenging when the catheter becomes entrapped, precluding conventional extraction methods.

Observation:

  • A 9-year-old girl presented with a systemic infection linked to an entrapped PAC.
  • Standard removal techniques were unsuccessful due to the catheter being trapped.

Findings:

  • The entrapped PAC was successfully extracted using a laser technique.
  • This method leveraged experience from pacemaker and implantable cardioverter defibrillator lead extraction.

Implications:

  • Laser extraction offers a viable, less invasive alternative for complex, entrapped PAC removal in pediatric patients.
  • This technique can potentially prevent the need for more invasive surgical procedures like open-heart surgery.