Revision total hip arthroplasty for ceramic head fracture: a long-term follow-up
Vineet Sharma1, Amar S Ranawat, Vijay J Rasquinha
1Ranawat Orthopaedic Center, Lenox Hill Hospital, New York, New York 10021, USA.
Abstract:
The results of revision total hip arthroplasty (THA) for ceramic head fracture have generally been disappointing, largely due to third body wear after incomplete synovectomy. We have followed 8 patients who sustained ceramic head fractures and were subsequently revised to a metal-on-polyethylene articulation. There were no revisions for osteolysis or aseptic loosening at a mean follow-up of 10.5 years. The yearly wear rates of each of 5 of these THAs after revision were compared with 6 matched metal-on-polyethylene THAs; there were no significant differences in wear rates. Greater than 10-year survivorship with a metal-on-polyethylene bearing couple is possible after revision THA for a ceramic head fracture if a complete and thorough synovectomy can be performed. Our technique of synovectomy will be described.