Related Experiment Video
Updated: Jun 14, 2026

NADH Fluorescence Imaging of Isolated Biventricular Working Rabbit Hearts
Published on: July 24, 2012
Do electrical parameters of the cardiac cycle reflect the corresponding mechanical intervals as the heart rate
Eraldo Occhetta1, Giorgio Corbucci, Miriam Bortnik
1SCDU Cardiologia 1, Azienda Ospedaliero-Universitaria Maggiore della Carità, Novara, Italy. occhetta@r-j.it
Aims:
The evoked QT interval can be detected beat by beat through an implanted pacing system. The correlation between the right ventricular paced QT interval and the left ventricular systolic interval is not known. The aim of our study was to collect data on the correlation between QT and systolic and diastolic indexes at different heart rates in patients with dual-chamber rate-responsive pacemakers.
Method And Results:
The study involved 13 patients [67 +/- 9 years; ejection fraction (EF) 52 +/- 10%] with standard indication for dual-chamber pacing. Patients were evaluated at rest in the supine position. The AV delay was set at 130 ms, and the pacing rate was increased from 90 to 130 bpm (10 bpm steps for 3 min). At the end of each 3 min step, QT intervals were automatically evaluated in real time by means of pacemaker telemetry. We also evaluated heart performance by means of echo-2D (end-diastolic/end-systolic volumes, EF) and echo-Doppler measurements [left ventricular ejection time (LVET) and diastolic filling time (LVDFT), aortic velocity time integral, and systolic volume] and systemic arterial pressure. The QT interval progressively decreased from 330 +/- 20 to 280 +/- 10 ms as the pacing rate was increased from 90 to 130 bpm. The correlation between the QT interval and LVET as a function of the pacing rate was R(2) = 0.966, indicating a good and relatively parallel trend in these two parameters. The correlation between RR-QT (reflecting electrical diastole) and LVDFT (reflecting mechanical diastole) was R(2) = 0.975. The index LVET/QT (ratio between mechanical and electrical systole) was constant in the range 90-120 bpm, but significantly decreased at 130 bpm: the mechanical LVET shortens more than the electrical QT does at the highest heart rates.
Conclusion:
In paced patients at rest and during artificially increased heart rates, QT interval dynamics is closely correlated with changes in ejection time, thus constituting an electrical parameter of systolic time. A similar correlation exists between RR-QT, as a diastolic electrical interval, and the DFT.
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Cardiac Cycle
During the cardiac cycle, blood flow through the heart is regulated entirely by changing pressure gradients. This sequence of events begins with the heart in a state of total relaxation, known as mid-to-late diastole, during which blood passively flows from...
The Cardiac Cycle
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and empty blood into the...
Electrophysiology of Normal Cardiac Rhythm
Physiology of the Heart: The Cardiac Cycle
Diastole: The Relaxation Phase
During diastole, all four heart chambers relax. The atrioventricular (AV) valves open, and the semilunar valves close. This phase sees the lowest chamber pressures, promoting ventricular filling. Venous blood enters the heart through the...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials