Visual impact of Zernike and Seidel forms of monochromatic aberrations
Xu Cheng1, Arthur Bradley, Sowmya Ravikumar
1School of Optometry, Indiana University, Bloomington, Indiana 47405, USA.
Purpose:
The aim of this study was to examine the impact of different aberrations modes (e.g., coma, astigmatism, spherical aberration [SA]) and different aberration basis functions (Zernike or Seidel) on visual acuity (VA).
Methods:
Computational optics was used to generate retinal images degraded by either the Zernike or Seidel forms of second through fourth-order aberrations for an eye with a 5-mm pupil diameter. High contrast, photopic VA was measured using method of constant stimuli for letters displayed on a computer-controlled, linearized, quasimonochromatic (lambda = 556 nm) display.
Results:
Minimum angle of resolution (MAR) varied linearly with the magnitude (root mean square error) of all modes of aberration. The impact of individual Zernike lower- and higher-order aberrations (HOAs) varied significantly with mode, e.g., arc minutes of MAR per micrometer of root mean square slopes varied from 7 (spherical defocus) to 0.5 (quadrafoil). Seidel forms of these aberrations always had a smaller visual impact. Notably, Seidel SA had 1/17th the impact of Zernike SA with the same wavefront variance, and about 1/4th the impact of Zernike SA with matching levels of r wavefront error. With lower-order components removed, HOAs near the center of the Zernike pyramid do not have a large visual impact.
Conclusions:
The majority of the visual impact of high levels of fourth-order Zernike aberrations can be attributed to the second-order terms within these polynomials. Therefore, the impact of SA can be minimized by balancing it with a defocus term that flattens the central wavefront (paraxial focus) or maximizes the area of the pupil with a flat wavefront. Over this wide range of aberration types and levels, image quality metrics based on the Point Spread Function (PSF) and Optical Transfer Function (OTF) can predict VA as reliably as VA measures can predict retests of VA, and, thus, such metrics may become valuable predictors of both VA and, via optimization, refractions.
Related Concept Videos
Interference and Diffraction
Focusing of Light in the Eye
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...