Novel application of MRI technique combined with flow-through cell dissolution apparatus as supportive discriminatory
Przemyslaw P Dorozyński1, Piotr Kulinowski, Aleksander Mendyk
1Department of Pharmaceutical Technology and Biopharmaceutics, Pharmaceutical Faculty, Jagiellonian University, ul. Medyczna 9, 30-688, Kraków, Poland. mfdorozy@cyf-kr.edu.pl
Abstract:
Dissolution studies cannot distinguish phenomena occurring inside the dosage forms when studying formulation with similar dissolution profiles-such formulations can behave differently when considering their physical changes. The application of flow-through dissolution apparatus integrated with magnetic resonance imaging (MRI) system for discriminative evaluation of controlled release dosage forms with similar dissolution profiles was presented. Hydrodynamically balanced systems (HBS) containing L: -dopa and various grades hydroxypropyl methylcelluloses were prepared. The dissolution studies of L: -dopa were performed at high field (4.7 T) MR system with MR-compatible flow-through cell. MRI was done with 0.14 x 0.14 x 1-mm spatial resolution and temporal resolution of 10 min to record changes of HBS parameters during dissolution in 0.1 M HCl. Structural and geometrical changes were evaluated using the following parameters: total area of HBS cross-section, its Feret's diameter, perimeter and circularity, area of hydrogel layer, and "dry core" area. While the dissolution profiles of L: -dopa were similar, the image analysis revealed differences in the structural and geometrical changes of the HBS. The mechanism of drug release from polymeric matrices is a result of synergy of several different phenomena occurring during dissolution and may differ between formulations, yet giving similar dissolution profiles. A multivariate analysis was performed to create a model taking into account dissolution data, data from MRI, information about chemical structure, and polymer viscosity. It provided a single model for all the formulations which was confirmed to be competent. The presented method has merit as a potential Process Analytical Technology tool.
Related Concept Videos
In Vitro Drug Dissolution: Alternative Methods
In Vitro Drug Dissolution: Compendial Testing Models II
In Vitro Drug Dissolution: Compendial Testing Models I
In Vitro Drug Release Testing: Overview, Development and Validation
Methods for Studying Drug Absorption: In situ
The Doluisio method involves perfusing a prepared segment of a rat's small intestine with a solution of radiolabeled drug and a non-absorbable marker. This helps to differentiate between absorbed and non-absorbed drug concentrations. The intestinal segment is connected at both ends using tubing and syringes,...
Modified-Release Drug Delivery Systems: Bioavailability