Related Experiment Video
Updated: Jun 14, 2026

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Increasing selectivity in comprehensive three-dimensional gas chromatography via an ionic liquid stationary phase
W Christopher Siegler1, Jeffery A Crank, Daniel W Armstrong
1Department of Chemistry, Box 351700, University of Washington, Seattle, WA 98195-1700, USA.
Abstract:
Recent advances in improving the selectivity and performance for a comprehensive, three-dimensional (3D) gas chromatograph (GC(3)) instrument are described. With GC(3), two six-port diaphragm valves are utilized as the interfaces between three, in-series capillary columns housed in a standard GC instrument fitted with a high data acquisition rate flame ionization detector (FID). Modulation periods for sampling from one column to the next are set so that sufficient slices (i.e., modulations) are acquired by the subsequent dimension resulting in comprehensive data. We present GC(3) instrumentation with significantly higher 3D peak capacity than previously reported. An average peak capacity production (i.e., per time) of 180 resolved peaks per minute was experimentally achieved for three representative analytes in a 3D diesel sample separation. This peak capacity production is about 4 times higher than our previous report. We also demonstrate the significant benefit of the added chemical selectivity of the three column GC(3) instrument relative to a two column GC x GC instrument, in which one of the three columns is a triflate ionic liquid stationary phase column with a high selectivity for phosphonated compounds (i.e., di-methyl-methyl phosphonate, di-ethyl-methyl phosphonate and di-isopropyl-methyl phosphonate). Using all three separation dimensions, the 2D separation fingerprint of a diesel sample is simultaneously obtained along with selective information regarding the phosphonated compounds in the diesel samples in the additional dimension.
More Related Videos
10:14Synthesis and Purification of Iodoaziridines Involving Quantitative Selection of the Optimal Stationary Phase for Chromatography
Published on: May 16, 2014
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
High-Performance Liquid Chromatography: Elution Process
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...