Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Jun 14, 2026

Microfabricated Post-Array-Detectors (mPADs): an Approach to Isolate Mechanical Forces
61:34

Microfabricated Post-Array-Detectors (mPADs): an Approach to Isolate Mechanical Forces

Published on: October 1, 2007

Platelet retraction force measurements using flexible post force sensors.

Xin M Liang1, Sangyoon J Han, Jo-Anna Reems

  • 1Department of Mechanical Engineering, University of Washington, Seattle, USA.

Lab on a Chip
|April 2, 2010
PubMed
Summary

This study introduces a novel method to measure platelet contractile forces (PCF) in microthrombi. The new technique quantifies PCF, crucial for hemostasis and thrombosis, offering insights into platelet function.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

High-Throughput Focal Adhesion Analysis Software for Automated Detection, Tracking, and Classification of Cell-Matrix Adhesions.

Current protocols·2026
Same author

The E525K β-Myosin Mutation Causes Hypocontractility in Cardiomyocytes Without Altering Loaded Crossbridge Cycling.

bioRxiv : the preprint server for biology·2026
Same author

ERK builds a population of short-lived nascent adhesions that produce persistent edge protrusion and cell migration.

Proceedings of the National Academy of Sciences of the United States of America·2026
Same author

Generation of WTC11 CLYBL-CAG_GCaMP8f cell line for fast and sensitive calcium tracking.

Stem cell research·2026
Same author

Albumin dialysis modeling predicts the impact of polysulfone dialyzers and flow rate on cholic acid and indoxyl sulfate removal.

The International journal of artificial organs·2026
Same author

Regulated RIAM-Talin Engagement Controls Adhesion Stability and Mechanical Output.

bioRxiv : the preprint server for biology·2026

Area of Science:

  • Biophysics
  • Hematology
  • Biomedical Engineering

Background:

  • Platelets are vital for hemostasis, forming plugs and promoting healing.
  • Platelet contractile forces (PCF) are key to thrombus retraction and adhesion.
  • Direct measurement of PCF remains challenging.

Purpose of the Study:

  • To develop and validate a novel approach for measuring PCF in microthrombi.
  • To quantify PCF under various hemostatic conditions.
  • To assess the force generated per platelet.

Main Methods:

  • Development of a microscopic flexible post force sensor array.
  • Quasi-static measurements and live microscopic imaging of thrombin-activated platelets.
  • Assay of PCF development in response to thrombin concentration and activation time.

More Related Videos

Directly Measuring Forces Within Reconstituted Active Microtubule Bundles
07:47

Directly Measuring Forces Within Reconstituted Active Microtubule Bundles

Published on: May 10, 2022

Easy and Accurate Mechano-profiling on Micropost Arrays
10:25

Easy and Accurate Mechano-profiling on Micropost Arrays

Published on: November 17, 2015

Related Experiment Videos

Last Updated: Jun 14, 2026

Microfabricated Post-Array-Detectors (mPADs): an Approach to Isolate Mechanical Forces
61:34

Microfabricated Post-Array-Detectors (mPADs): an Approach to Isolate Mechanical Forces

Published on: October 1, 2007

Directly Measuring Forces Within Reconstituted Active Microtubule Bundles
07:47

Directly Measuring Forces Within Reconstituted Active Microtubule Bundles

Published on: May 10, 2022

Easy and Accurate Mechano-profiling on Micropost Arrays
10:25

Easy and Accurate Mechano-profiling on Micropost Arrays

Published on: November 17, 2015

Main Results:

  • Microthrombi generated forces that increased with thrombin concentration and time, subsiding upon thrombin removal.
  • PCF measurements were consistent on fibronectin and fibrinogen coated posts.
  • Average force per platelet was determined to be 2.1 +/- 0.1 nN after 60 minutes.

Conclusions:

  • The flexible post array is a promising tool for measuring PCF.
  • This method can evaluate platelet functionality, pathology, and responses to matrices/agonists.