Related Experiment Video
Updated: Jun 14, 2026

Functional Imaging of Brown Fat in Mice with 18F-FDG micro-PET/CT
Published on: November 23, 2012
Brown fat uptake of 18F-FDG on dual time point PET/CT imaging
A R Hairil Rashmizal1, A R Noraini, C Rossetti
1Discipline of Medical Radiations, School of Medical Sciences, Bundoora West Campus, Royal Melbourne Institute of Technology University, Bundoora, Victoria 3083, Australia.
The aim of this report was to assess the changes in the 18F-fluorodeoxyglucose (18F-FDG) uptake of brown fats on integrated positron emission tomography/computed tomography (PET/CT) imaging. The patient presented with an enlargement of the neck lymph nodes, and was suspicious for tuberculous lymphadenitis. A whole body PET/CT imaging was performed, followed by a delayed imaging of the neck and thoracic regions. A visually increased 18F-FDG uptake was taken as a positive finding. A semi-quantitative evaluation was performed using a maximum standardised uptake value (SUVmax), with a cut-off value above 2.5. There were a number of 18F-FDG avid activity areas seen at the supraclavicular, mediastinal, paravertebral and perirenal regions. These are in keeping with the physiological 18F-FDG uptake in brown fat. The differences in SUVmax between the two images ranged from -20 percent to +20 percent. Based on our observations, dual time point imaging may not be a reliable method for assessing the 18F-FDG uptake of brown fat.
The aim of this report was to assess the changes in the 18F-fluorodeoxyglucose (18F-FDG) uptake of brown fats on integrated positron emission tomography/computed tomography (PET/CT) imaging. The patient presented with an enlargement of the neck lymph nodes, and was suspicious for tuberculous lymphadenitis. A whole body PET/CT imaging was performed, followed by a delayed imaging of the neck and thoracic regions. A visually increased 18F-FDG uptake was taken as a positive finding. A semi-quantitative evaluation was performed using a maximum standardised uptake value (SUVmax), with a cut-off value above 2.5. There were a number of 18F-FDG avid activity areas seen at the supraclavicular, mediastinal, paravertebral and perirenal regions. These are in keeping with the physiological 18F-FDG uptake in brown fat. The differences in SUVmax between the two images ranged from -20 percent to +20 percent. Based on our observations, dual time point imaging may not be a reliable method for assessing the 18F-FDG uptake of brown fat.
More Related Videos
10:30Whole Body and Regional Quantification of Active Human Brown Adipose Tissue Using 18F-FDG PET/CT
Published on: April 1, 2019
09:21Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
Published on: February 18, 2015
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET