Bone cutting.

J Y Giraud1, S Villemin, R Darmana

  • 1INSERM U 305, Centre Hospitalier Hôtel-Dieu, Toulouse, France.

Clinical Physics and Physiological Measurement : an Official Journal of the Hospital Physicists' Association, Deutsche Gesellschaft Fur Medizinische Physik and the European Federation of Organisations for Medical Physics
|February 1, 1991
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Effect of Tibial Plateau Levelling Osteotomy on Cranial Tibial Subluxation in the Feline Cranial Cruciate Deficient Stifle Joint: An Ex Vivo Experimental Study.

Veterinary and comparative orthopaedics and traumatology : V.C.O.T·2018
Same author

<i>In situ</i> pinning in slipped capital femoral epiphysis: long-term follow-up studies.

Journal of children's orthopaedics·2017
Same author

Effect of tibial tuberosity advancement on cranial tibial subluxation in the feline cranial cruciate deficient stifle joint: An ex vivo experimental study.

Research in veterinary science·2016
Same author

Biomechanical comparison of two locking plate constructs under cyclic torsional loading in a fracture gap model. Two screws versus three screws per fragment.

Veterinary and comparative orthopaedics and traumatology : V.C.O.T·2015
Same author

Ex vivo cyclic mechanical behaviour of 2.4 mm locking plates compared with 2.4 mm limited contact plates in a cadaveric diaphyseal gap model.

Veterinary and comparative orthopaedics and traumatology : V.C.O.T·2013
Same author

Dual mobility canine total hip prosthesis: implant characteristics and surgical procedure.

Veterinary and comparative orthopaedics and traumatology : V.C.O.T·2012
Same journal

Changes of erythropoietic and storage iron components in certain clinical situations as evaluated by ferrokinetic investigations.

Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics·1992
Same journal

An error study on some linear reconstruction algorithms for electrical impedance tomography.

Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics·1992
Same journal

Effects of myocardial electrotonic interaction on the sequence of excitation and repolarisation and on T wave polarity. Computer modelling experiments.

Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics·1992
Same journal

Spectrophotometric measurements of haemoglobin saturation and concentration in skin during the tuberculin reaction in normal human subjects.

Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics·1992
Same journal

Antimony electrode for the determination of the intramyocardial pH during open-heart surgery.

Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics·1992
Same journal

A thermal clearance probe for continuous monitoring of cerebral blood flow.

Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics·1992
See all related articles

Surgical bone cutting remains challenging due to bone's hardness. While motorized and non-conventional tools like ultrasonic osteotomes show promise, further advancements are needed for widespread surgical adoption.

Area of Science:

  • Orthopedic Surgery
  • Biomedical Engineering
  • Surgical Instrumentation

Background:

  • Bone cutting presents significant challenges for surgeons due to the material properties of bone.
  • Traditional osteotomes are often considered crude, necessitating technological advancements in surgical tools.
  • Motorization represented an initial step in improving conventional bone-cutting instruments.

Purpose of the Study:

  • To review and evaluate advancements in bone-cutting technologies for surgical applications.
  • To explore the efficacy and limitations of both conventional and non-conventional osteotomes.
  • To identify areas for future development in surgical bone cutting tools.

Main Methods:

  • Review of existing literature on bone cutting techniques and tools.

Related Experiment Videos

  • Analysis of studies comparing conventional and non-conventional osteotomes.
  • Examination of emerging technologies such as ultrasonic osteotomes, lasers, and water jet systems.
  • Main Results:

    • Motorized conventional tools offer improved performance over basic instruments.
    • Non-conventional tools, including ultrasonic osteotomes, lasers, and water jets, demonstrate potential advantages.
    • Current non-conventional bone-cutting technologies still require further refinement for optimal surgical use.

    Conclusions:

    • Advancements in surgical tools have improved bone cutting, but challenges persist.
    • Non-conventional technologies like ultrasonic osteotomes show promise but need further development.
    • Future research should focus on enhancing the precision and applicability of novel bone-cutting instruments for surgeons.