[Comparison of lung volume response with airflow response to bronchodilator in patients with chronic obstructive
Fu-Qiang Zhang1, Jin-Ping Zheng, Jia-Hong Wang
1First Clinical Department, First TeachingCollege of Guangzhou Medical University, First Affiliated Hospital of Guangzhou Medical University, Guangzhou 510120, China.
Objective:
the reversibility of chronic obstructive pulmonary disease (COPD) is evaluated mainly by FEV(1) after bronchodilators. However, lung volumes also change significantly in COPD, but few studies addressed the characteristics of the changes in post bronchodilator airflow and lung volume in patients with COPD. This study was carried out to evaluate the difference of FEV(1) response and forced vital capacity (FVC) response to bronchodilators in patients with COPD as well as the impact of severity of COPD on the flow and volume reversibility.
Methods:
465 patients with COPD (male 426, female 39), aged 67.1 +/- 8.3 (42 approximately 86) yrs were enrolled from Jan. 2006 to Aug. 2008. The severity of COPD was graded according to the GOLD criteria. The change and rate of change of FVC and FEV(1) 20 minutes after inhalation of salbutamol 400 microg via spacer were measured and compared. Positive response to the bronchodilator was determined as FEV(1) or FVC increased 12% as well as 200 ml or above. The impacts of severity on flow and volume response were also studied.
Results:
post-bronchodilator FEV(1) increased 117 ml with a 13.2% improvement on average compared with baseline. Post-bronchodilator FVC increased 258 ml and improved by 14.0% on average. The rate of positive reversibility in FEV(1) and FVC was 18.7% (87/465) and 44.1% (205/465), respectively. The improvement of FEV(1) decreased as a function of the severity of COPD. In contrast, the improvement of FVC was increased in those with more severe disease.
Conclusion:
the improvement of lung volume is more significant and maybe more important than airflow response in patients with COPD, especially in those with severe disease. In addition to FEV(1), the reversibility of COPD should also be evaluated by FVC.
Related Concept Videos
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...
Chronic Obstructive Pulmonary Disease III: Chronic Bronchitis Features
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Chronic Obstructive Pulmonary Disease-I: Introduction