Related Experiment Video
Updated: Jun 14, 2026

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
Parameters of passive fit using a new technique to mill implant-supported superstructures: an in vitro study of a
Ali Tahmaseb1, J J van de Weijden, Peter Mercelis
1Department of Oral Implantology and prosthetics, Academic centre for dentistry Amsterdam, University of Amsterdam, Amsterdam, The Netherlands. a.tahmaseb@acta.nl
Purpose:
The objectives of this study are to describe, in vitro, a novel technique to measure the misfit of digitally designed and manufactured implant-supported frameworks according to a new concept based on computer-guided surgery in combination with previously placed mini-implants. Also, the digitally created framework and an impression-based milled structure were compared using strain gauge measurements.
Materials And Methods:
Acrylic resin and plaster models were prepared to represent the edentulous mandible. After insertion of three mini-implants in the acrylic resin model, a cone-beam computed tomographic scan was performed. The data were imported to planning software, where six implants were virtually inserted. A drill guide and titanium framework were designed and milled using a fully digital computer-aided design/computer-assisted machining protocol. Six implants were inserted using the drill guide attached to the mini-implants. After an impression was made of the acrylic resin model with six implants, the second model (plaster model) was prepared. A second milled titanium structure was fabricated following optical scanning of the acrylic resin model. Strain gauge measurements were done on both structures attached to both models. To validate the results, a high-accuracy industrial optical scanning system was used to capture all connection geometry and the measurements were compared.
Results:
The accuracy of the digital superstructures was 19, 22, and 10 Microm with standard deviations (SD) of 19.2 (17.9), 21.5 (28.3), and 10.3 (10.1) Microm for the x-, y-, and z-axes, respectively. For the impression-based superstructure the measured misfit was 11, 20, and 17 Microm, with SD 11.8 (10.5), 19.7 (11.7), and 16.7 (8.2) Microm for the x-, y-, and z-axes, respectively.
Conclusion:
The misfit of the digitally designed and produced superstructure on the digitally planned and inserted implants was clinically insignificant.