Related Experiment Video
Updated: Jun 14, 2026

Fat-Water Phantoms for Magnetic Resonance Imaging Validation: A Flexible and Scalable Protocol
Published on: September 7, 2018
[Quantification of pancreas fat by MRS and FATSAT with 3.0T MRI]
Fang Yuan1, Bin Song, He-Han Tang
1Department of Radiology, West China Hospital, Sichuan University, Chengdu, China.
Objective:
To test the values of MR spectroscopy (MRS) and fat saturation (FATSAT) in quantifying fat content in pancreas with 3.0T MR.
Methods:
Thirty-five healthy volunteers were examined with 3 different MR techniques IP/OP, MRS, and FATSAT, to quantify pancreas fat content (FC). The IP/OP result served as a reference standard.
Results:
The IP/OP, FATSAT and MRS detected (8.2 +/- 2.0)%, (11.8 +/- 4.7)% and (8.8 +/- 4.6)% of pancreas fat content, respectively. The IP/OP result correlated with the MRS result (r = 0.809, P < 0.001), but not with the FATSAT result (r = 0.311, P = 0.069).
Conclusion:
For 3.0T MRI, MRS technique can quantify pancreas fat content, but FATSAT can not.