Assessment of a cardiac output device using arterial pulse waveform analysis, Vigileo, in cardiac surgery compared to
1Department of Anesthesiology, University Hospital la Cavale Blanche, Boulevard Tanguy Prigent, Brest, France.
Abstract:
Many devices are available to assess cardiac output (CO) in critically ill patients and in the operating room. Classical CO monitoring via a pulmonary artery catheter involves continuous cardiac output (CCO) measurement. The second generation of Flotrac/Vigileo monitors propose an analysis of peripheral arterial pulse waves to calculate CO (APCO) without calibration. The aim of our study was to compare the CO between the Swan Ganz catheter and the VigileoT. In this observational study, nine patients undergoing coronary artery bypass grafting were prospectively included. APCO, mean (CCO) and instantaneous CO (ICO) were measured. Perioperative and postoperative assessments were performed up to 24 hours post-surgery. Measurements were recorded every minute, resulting in the collection of 6492 data pairs. Comparison of APCO and ICO showed a limited bias of -0.1 l/min but an important percentage error of 48%. Corresponding values were -0.1 l/min and 46% for the APCO versus CCO comparison, and 0 and 17% for ICO versus CCO comparison. Large inter-individual variability does exist. During cardiac surgery and after leaving the operating room, Vigileo is not clinically equivalent to continuous thermodilution by pulmonary artery catheter Nevertheless, the connection between CCO and ICO relates the difference between APCO and CCO more to the different algorithms used. Further efforts should be concentrated on assessing the ability of this device to track changes in cardiac output.
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: