Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
Atomic Emission Spectroscopy: Instrumentation01:22

Atomic Emission Spectroscopy: Instrumentation

The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers.  Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle01:19

Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle

Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Emission Spectroscopy: Overview01:20

Atomic Emission Spectroscopy: Overview

Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Tomographic reconstruction of sound fields using TV holography.

Applied optics·2010
Same author

Measurement of higher harmonics in periodic vibrations using phase-modulated TV holography with digital image processing.

Applied optics·2010
Same author

Sound in flight: measurement of sound fields by use of TV holography.

Applied optics·2010
Same author

Effect and use of exposure control in vibration analysis using TV holography.

Applied optics·2010
Same author

Electronic speckle pattern interferometric measurements of the basilar membrane in the inner ear.

Applied optics·2010
Same author

Interferometric comparison of displacements by electronic speckle pattern interferometry.

Applied optics·2010
Same journal

Multifunctional reconfigurable terahertz metasurface based on vanadium dioxide phase transition: achieving broadband absorption and efficient polarization conversion.

Applied optics·2026
Same journal

High-Q-factor electromagnetically induced transparency utilizing quasi-bound states in the continuum in an all-dielectric terahertz metasurface.

Applied optics·2026
Same journal

Automated stitching interferometry for high-precision metrology of X-ray mirrors.

Applied optics·2026
Same journal

Experimental demonstration of an approach to designing a metal-dielectric DBR resonant cavity structure.

Applied optics·2026
Same journal

High-precision wavefront reconstruction from a single-shot interferogram using a physics-driven hybrid feature calibration network.

Applied optics·2026
Same journal

Ultra-high-Q Fano resonance based on coupled topological corner states in Kagome photonic crystals.

Applied optics·2026
See all related articles

Related Experiment Video

Updated: Jun 14, 2026

Live Cell Imaging of F-actin Dynamics via Fluorescent Speckle Microscopy (FSM)
19:16

Live Cell Imaging of F-actin Dynamics via Fluorescent Speckle Microscopy (FSM)

Published on: August 5, 2009

Speckle reference ESPI: in practice

G A Slettemoen, O J Løkberg

    Applied Optics
    |April 8, 2010
    PubMed
    Summary

    No abstract available in PubMed .

    More Related Videos

    Assessing Intracardiac Vortices with High Frame-Rate Echocardiography-Derived Blood Speckle Imaging in Newborns
    07:13

    Assessing Intracardiac Vortices with High Frame-Rate Echocardiography-Derived Blood Speckle Imaging in Newborns

    Published on: December 22, 2023

    Spectral Reflectometric Microscopy on Myelinated Axons In Situ
    09:13

    Spectral Reflectometric Microscopy on Myelinated Axons In Situ

    Published on: July 2, 2018

    Related Experiment Videos

    Last Updated: Jun 14, 2026

    Live Cell Imaging of F-actin Dynamics via Fluorescent Speckle Microscopy (FSM)
    19:16

    Live Cell Imaging of F-actin Dynamics via Fluorescent Speckle Microscopy (FSM)

    Published on: August 5, 2009

    Assessing Intracardiac Vortices with High Frame-Rate Echocardiography-Derived Blood Speckle Imaging in Newborns
    07:13

    Assessing Intracardiac Vortices with High Frame-Rate Echocardiography-Derived Blood Speckle Imaging in Newborns

    Published on: December 22, 2023

    Spectral Reflectometric Microscopy on Myelinated Axons In Situ
    09:13

    Spectral Reflectometric Microscopy on Myelinated Axons In Situ

    Published on: July 2, 2018