Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview01:02

Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview

Ultraviolet–visible (UV–visible or UV–Vis) spectroscopy is an analytical technique that investigates the interaction between matter and UV–Vis light within the electromagnetic spectrum. This method is widely used for its versatility, simplicity, and relatively quick data acquisition, making it valuable for both qualitative and quantitative analysis. When UV–Vis radiation passes through a material,  molecules absorb light depending on the energy required for electronic transitions. As a result...
UV–Vis Spectroscopy: Molecular Electronic Transitions01:16

UV–Vis Spectroscopy: Molecular Electronic Transitions

In Ultraviolet–Visible (UV–Vis) spectroscopy, the absorption of electromagnetic radiation is used to probe the electronic structure of molecules. This technique provides insights into molecular electronic transitions, particularly the movement of electrons between different molecular orbitals. Radiation is absorbed if the energy of the electromagnetic radiation passing through the molecule is precisely equal to the energy difference between the excited and ground states. During this process,...
IR Spectrometers01:25

IR Spectrometers

There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
UV–Vis Spectrum01:30

UV–Vis Spectrum

When light passes through a substance, a portion of the light is absorbed while the remaining light is reflected or transmitted. If the molecule absorbs light between the wavelengths of 180–400 nm range, the UV spectrum is obtained, and if it absorbs light in the 400–780 nm wavelength range, the visible spectrum is obtained.     
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar absorptivity (ε) or log ε on the y-axis (ordinate)...
UV–Vis Spectroscopy of Conjugated Systems01:32

UV–Vis Spectroscopy of Conjugated Systems

Organic compounds with conjugated double bonds show strong absorption features in the UV–visible region of the electromagnetic spectrum attributed to π → π* electronic excitations. Generally, a UV–vis absorption spectrum is recorded as a plot of absorbance vs wavelength. The wavelength of maximum absorbance, which manifests as a peak in the absorption spectrum, is denoted as λmax.
One of the factors influencing λmax is the extent of conjugation in the...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Assessing service usage and protective factors in a pediatric psychiatry clinic during the COVID-19 pandemic.

Frontiers in psychology·2024
Same author

Robust Evaluation of Ultraviolet-C Sensitivity for SARS-CoV-2 and Surrogate Coronaviruses.

Microbiology spectrum·2021
Same author

A comprehensive scoring system to evaluate patient-centred risk factors regarding lower extremity amputation.

Journal of wound care·2017
Same author

Subduction-driven recycling of continental margin lithosphere.

Nature·2014
Same author

Dynamics of continental accretion.

Nature·2014
Same author

A technique for murine irradiation in a controlled gas environment.

Biomedical sciences instrumentation·2012

Related Experiment Video

Updated: Jun 14, 2026

Indoor Experimental Assessment of the Efficiency and Irradiance Spot of the Achromatic Doublet on Glass (ADG) Fresnel Lens for Concentrating Photovoltaics
09:00

Indoor Experimental Assessment of the Efficiency and Irradiance Spot of the Achromatic Doublet on Glass (ADG) Fresnel Lens for Concentrating Photovoltaics

Published on: October 27, 2017

Ultraviolet spectrometer and polarimeter for the Solar Maximum Mission.

M S Miller, A J Caruso, B E Woodgate

    Applied Optics
    |April 8, 2010
    PubMed
    Summary

    The Solar Maximum Mission-Ultraviolet Spectrometer and Polarimeter features an advanced optical design for solar observation. Its components include a Gregorian telescope and Ebert spectrometer for detailed ultraviolet analysis.

    More Related Videos

    Measurement of Aerosols Optical Thickness of the Atmosphere using the GLOBE Handheld Sun Photometer
    06:27

    Measurement of Aerosols Optical Thickness of the Atmosphere using the GLOBE Handheld Sun Photometer

    Published on: May 29, 2019

    Evaluation of Photosynthetic Behaviors by Simultaneous Measurements of Leaf Reflectance and Chlorophyll Fluorescence Analyses
    10:20

    Evaluation of Photosynthetic Behaviors by Simultaneous Measurements of Leaf Reflectance and Chlorophyll Fluorescence Analyses

    Published on: August 9, 2019

    Related Experiment Videos

    Last Updated: Jun 14, 2026

    Indoor Experimental Assessment of the Efficiency and Irradiance Spot of the Achromatic Doublet on Glass (ADG) Fresnel Lens for Concentrating Photovoltaics
    09:00

    Indoor Experimental Assessment of the Efficiency and Irradiance Spot of the Achromatic Doublet on Glass (ADG) Fresnel Lens for Concentrating Photovoltaics

    Published on: October 27, 2017

    Measurement of Aerosols Optical Thickness of the Atmosphere using the GLOBE Handheld Sun Photometer
    06:27

    Measurement of Aerosols Optical Thickness of the Atmosphere using the GLOBE Handheld Sun Photometer

    Published on: May 29, 2019

    Evaluation of Photosynthetic Behaviors by Simultaneous Measurements of Leaf Reflectance and Chlorophyll Fluorescence Analyses
    10:20

    Evaluation of Photosynthetic Behaviors by Simultaneous Measurements of Leaf Reflectance and Chlorophyll Fluorescence Analyses

    Published on: August 9, 2019

    Area of Science:

    • Solar physics
    • Space instrumentation
    • Ultraviolet spectroscopy

    Background:

    • Understanding solar activity requires specialized instruments.
    • Previous missions have provided valuable solar data.
    • The need for high-resolution ultraviolet observations of the sun.

    Purpose of the Study:

    • To detail the optical design of the Solar Maximum Mission-Ultraviolet Spectrometer and Polarimeter (SMUVP).
    • To align the instrument's design with specific scientific objectives for solar research.
    • To present the design of the integrated Stokes polarimeter.

    Main Methods:

    • Optical design of a 1.8-m effective focal length aplanatic Gregorian telescope.
    • Integration of a 1-m Ebert spectrometer.
    • Design specifications for the Stokes polarimeter.

    Main Results:

    • A comprehensive optical design for the SMUVP.
    • Successful integration of telescope, spectrometer, and polarimeter.
    • The design meets the scientific objectives for ultraviolet solar studies.

    Conclusions:

    • The SMUVP optical design is robust and scientifically driven.
    • The instrument is poised to advance solar physics research.
    • Further analysis and calibration are planned for the instrument.