Related Experiment Video
Updated: Jun 14, 2026

Design and Use of a Full Flow Sampling System (FFS) for the Quantification of Methane Emissions
Published on: June 12, 2016
Factors affecting the location and shape of face seal leak sites on half-mask respirators
Riedar Kent Oestenstad1, Alfred A Bartolucci
1University of Alabama at Birmingham, School of Public Health, Department of Environmental Health Sciences, Birmingham, Alabama 35924-0022, USA. oestk@uab.edu
Abstract:
While there have been a number of studies on the effect of leak site and shape on the magnitude of measured leakage through respirator face seals, there have been very few studies to identify the location and size of these leaks. In a previous study we used a method of identifying the location and shape of respirator leaks on a half-mask respirator by the deposition of a fluorescent tracer during a fit test, and testing for their association with facial dimensions. The purpose of this study was to apply that methodology to conduct multiple fit tests to determine if gender, respirator brand, repeated fit tests, and test exercises affected the location and shape of face seal leak sites. Categorical analysis found that none of these factors had a significant effect on the location and shape of leaks. General linear model analysis found some significant effects of the study factors on leaks, but facial dimensions had a greater effect, and there were significant differences between facial dimensions of subjects with a leak and those without. Significant differences in leak site distributions between this and the previous study may have been due to differences in facial dimensions and racial/ethnic composition. Twice as many diffuse leaks as point leaks were observed in both studies, indicating that slit-like leaks would be most appropriate on mannequins used in laboratory respirator leakage studies, and in respirator flow and penetration models. That the study factors had no significant effects in the categorical analysis, significant effects for facial dimensions were found in the linear analysis, and leak site distribution differences between this and our previous study may have been affected by differences in facial dimensions, indicate that, in addition to size, the shape of an individual's face may be an important determinant of leak sites on a half-mask respirator. This would have implications for the design of respirator facepieces and in the selection of respirators for individual wearers.
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Cardiopulmonary Resuscitation II: ACLS Airway Management
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
PPE Use in Healthcare Settings I: Donning
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...