Related Experiment Video
Updated: Jun 14, 2026

Surface Enhanced Raman Spectroscopy Detection of Biomolecules Using EBL Fabricated Nanostructured Substrates
Published on: March 20, 2015
Surface-enhanced Raman spectroscopy of arsenate and arsenite using Ag nanofilm prepared by modified mirror reaction
Zhonghou Xu1, Jumin Hao, Fasheng Li
1Center for Environmental Systems, Stevens Institute of Technology, Hoboken, NJ 07030, USA.
Abstract:
A modified mirror reaction was developed to prepare a sensitive and reproducible Ag nanofilm substrate for the surface-enhanced Raman scattering (SERS) analysis of arsenate (As(V)) and arsenite (As(III)). A good linear relationship between the SERS intensity of As(V) and As(III) and their concentrations in the range from 10 to 500 microg-As/L was achieved using the SERS substrate. As(V) and As(III) appear to be adsorbed on the Ag nanofilm through formation of surface complexes with Ag, based on comparisons of the Raman spectra of the arsenic species in solutions, on the SERS substrate, and in silver arsenate and arsenite solids. As(V) and As(III) species on the SERS substrate and in the solids had the same Raman band positions at 780 and 721 cm(-1), respectively. The effect of eight ions in natural waters on the SERS analysis of As(V) was studied. K(+), Na(+), SO(4)(2-), CO(3)(2-), and NO(3)(-) in the range of 0.1-100 mg/L did not interfere with the SERS detection of As(V) for a As(V) concentration greater than 100 microg-As/L. While Cl(-) (50 mg/L), Mg(2+) (10 mg/L), and Ca(2+) (1 mg/L) were found to quench the SERS intensity of 100 microg/L As(V). Cl(-) (at concentrations >10 mg/L) formed silver chloride with the adsorbed Ag(+) and decreased the SERS detection limits for arsenic species. The mechanism of the Ca(2+) effect on the SERS analysis of As(V) was through the formation of surface complexes with As(V) in competition with Ag. When the Ca(2+) concentration increased from 0 to 100 mg/L, the amount of As(V) adsorbed in Ag nanoparticles was reduced from 38.9 to 11.0 microg/mg-Ag. When the Ca(2+) concentration increased to values higher than 1 mg/L in the As(V) solution, the As(V) peak height was decreased in the corresponding SERS spectra and the peak position shifted from 780 to 800 cm(-1). The fundamental findings obtained in this research are especially valuable for the development of sensitive and reliable SERS methods for rapid analysis of arsenic in contaminated water.
More Related Videos
10:59Tracking Electrochemistry on Single Nanoparticles with Surface-Enhanced Raman Scattering Spectroscopy and Microscopy
Published on: May 12, 2023
06:15Ultrafast Laser-Ablated Nanoparticles and Nanostructures for Surface-Enhanced Raman Scattering-Based Sensing Applications
Published on: June 16, 2023
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Fluorescence Spectroscopy