Related Experiment Video
Updated: Jun 13, 2026

Using Extraordinary Optical Transmission to Quantify Cardiac Biomarkers in Human Serum
Published on: December 13, 2017
Diagnosing acute myocardial infarction with troponins: how low can you go?
Richard Body1, Garry McDowell, Simon Carley
1Emergency Department, Hope Hospital, Stott Lane, Salford, Manchester M6 8HD, UK. rbody@doctors.org.uk
Background:
Recent consensus guidelines state that acute myocardial infarction (AMI) may be diagnosed in the context of a troponin rise above the 99th percentile of the upper reference limit (URL) with the optimal imprecision of the assay (coefficient of variation, CV) being
Methods:
The authors prospectively recruited 804 patients presenting to the Emergency Department of a university-affiliated teaching hospital with suspected ACS. All patients underwent 12 h troponin T testing and were followed up by telephone and chart review. Outcomes Death or AMI (excluding the index event) and the occurrence of major adverse cardiac events (MACEs) within 6 months.
Results:
Troponin T elevation below the functional sensitivity predicted the risk of death and AMI (adjusted OR 4.6, p=0.039) and MACE (adjusted OR 11.10, p<0.0001) independently of the Thrombolysis in Myocardial Infarction risk score and creatinine levels. Utilising the 99th percentile cut-off, an extra 17 MACEs could be predicted per 1000 patients treated at a cost of identifying 11 patients who would not have developed an event.
Conclusions:
The results suggest that adopting the lower troponin cut-off would reduce the proportion of 'false negatives' (patients with negative troponin who develop MACE) from 9.6% to 8.9%. Whether this reduction in 'false negatives' justifies the increase in 'false positives' warrants further investigation and discussion.
Related Concept Videos
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Acute Coronary Syndrome III: Diagnostic Studies
Acute Coronary Syndrome I: Introduction
Myocarditis II: Clinical Features and Diagnostic Tests
Acute Coronary Syndrome II: Pathophysiology and Clinical Manifestations
Acute Coronary Syndrome IV: Interprofessional Care
