Related Experiment Video
Updated: Jun 13, 2026

A Point-of-Care Method with Integrated Decision Support Tool to Estimate Anemia at Population Level
Published on: January 19, 2024
A portable blood analyzer that uses on-line data management to deliver higher-quality patient information
Masayuki Shibasaki1, Takae Ibuki, Yoshifumi Tanaka
1Department of Anesthesiology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kamigyo-ku, Kyoto, 602-8566, Japan.
Abstract:
We constructed an on-line data management system and linked it to the communication protocol of a portable blood analyzer (i-STAT) in each operating room of our institution. We developed a new program that integrates circulatory dynamics data from a monitor with laboratory data from the i-STAT. Our new program permits the results to be viewed through an intranet using a novel prototype communication device for the i-STAT 300F. We verified that this system can improve the quality of patient care both bedside and in the monitoring room and compared the costs of blood testing using a conventional desktop blood-gas analyzer and using the i-STAT. We found that the novel integration of circulatory dynamics with laboratory data enhanced the quality of intraoperative patient monitoring and reduced the cost and work load of doctors working in the operating room.
Related Concept Videos
Automated Microbial Diagnostics
Errors occurring during blood pressure monitoring
Several factors...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure in the Leg
Preparation:
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...
Health Information Technology and Healthcare Information System
Health Information Technology, commonly called HIT, integrates advanced information systems and technology in healthcare settings. Its primary functions include: