Related Experiment Video
Updated: Jun 13, 2026

Drug-Induced Sleep Endoscopy (DISE) with Target Controlled Infusion (TCI) and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
The role of sedation and pulse oximetry during upper gastrointestinal endoscopy
S K Sharma1, D K Maharjan, P B Thapa
1Department of Surgery, Kathmandu Medical College Teaching Hospital, Sinamangal, Kathmandu, Nepal. samknp@yahoo.com
Introduction:
To determine the changes in oxygen saturation, blood pressure and pulse rate during endoscopic procedure and to evaluate--oesophagogastroduodenoscopy (OGD) related discomfort assessed by the patient.
Methods:
It is observational case control study. Baseline pulse, blood pressure and oxygen saturation were monitored before procedure, at one minute of procedure, at five minute and soon after procedure. Patients were randomly selected according to lottery system (1: without sedation and 2: with sedation) and divided into two groups; without and with sedation. Before leaving department they were asked about level of discomfort during and after procedure.
Results:
Patient's mean age +/- SD: 36.65, +/- 11.42 years and 53.3% were men. Base line mean oxygen saturation among sedated patient were 96.77 +/-1.56 % and 97.23, +/- 2.26 % respectively (P = 0.358). Mild to moderate hypoxia was noted more in sedated patient than in non sedated patient. Severe hypoxia was noted in 3.3% of sedated patient. No statistically significant change was noticed in pulse and blood pressure in both the group. None or only slight discomfort was experienced by 9.4% in non sedated group and 90.6% in sedated group. Severe discomfort by 96.4% in non sedated group and 3.6% in sedated group.
Conclusions:
There is slight more incidence of mild hypoxia in sedated group than in non sedated group but no change in pulse and blood pressure. However, sedated patient have significant less level of discomfort than in non sedated group. Though routine use of pulse oxymeter is not necessary, routine use of sedation during endoscopy is recommended.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Endoscopic Procedures II: Colonoscopy