Related Experiment Video
Updated: Jun 13, 2026

Development of a Noninvasive, Laser-Assisted Experimental Model of Corneal Endothelial Cell Loss
Published on: April 24, 2020
Nonlinear refractive index of porcine cornea studied by z-scan and self-focusing during femtosecond laser processing
M Miclea1, U Skrzypczak, S Faust
1Martin-Luther-University Halle-Wittenberg, Physics Faculty, Optics Department, Von-Danckelmann-Platz 3, D-06120 Halle (Saale), Germany.
Abstract:
We have investigated the nonlinear refractive index of ex-vivo pig cornea by a combined approach using the standard z-scan technique on extracted corneas or corneal slices, as well as studying the deviations caused by self-focusing during femtosecond laser processing of the pig eyes. The experiments yield consistently an upper limit of 1.2 MW for the critical power of self-focusing in porcine cornea, and a value of 2 x 10(-19) m(2)/W for its nonlinear refractive index. We also demonstrate that due to this nonlinear refraction the cutting depth of typical fs-laser surgery processing in cornea may depend considerably, albeit in a well controllable way, on the laser parameters.