Related Experiment Video
Updated: Jun 13, 2026

Troubleshooting and Quality Assurance in Hyperpolarized Xenon Magnetic Resonance Imaging: Tools for High-Quality Image Acquisition
Published on: January 5, 2024
Unsupervised-clustering-driven noise-residue filter for phase images
Jun Jiang1, Jun Cheng, Bruno Luong
1Shenzhen Institute of Advanced Integration Technology, Chinese Academy of Sciences/The Chinese University of Hong Kong, 1068 Xueyuan Avenue, Shenzhen 518055, China.
Abstract:
We analyze the characteristics of noise-induced phase inconsistencies, or residues, in a wrapped phase map. Because residues are the potential source of phase-error propagation, it is essential to filter them before two-dimensional phase unwrapping. We propose an unsupervised-clustering-driven noise-residue filter, and apply it as a preprocessing procedure of phase unwrapping. The filter is based on the fact that most residues are present in the form of adjacency caused by noisy wrapped phases. These noisy phases differ from the other correct ones numerically within the local k(1) x k(2) window containing the adjacent residues, and it is possible to group the correct and noisy wrapped phases into different clusters. The window size is determined adaptively according to the local noise level. The proposed procedure avoids constructing branch cuts, and converts path-following unwrapping to path independence, which improves the operating speed of phase unwrapping significantly. The tests performed on simulated and real projected fringe patterns confirm the validity of our approach in residue reduction, fringe preservation, and rapidity.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Reconstruction of Signal using Interpolation
Cluster Sampling Method
To choose a cluster sample, divide the population into clusters (groups) and then randomly select some of the clusters. All the members from these clusters are in the cluster sample. For example, if you randomly sample four departments from your...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Parallel Resonance
Upsampling