Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Angular Momentum: Single Particle01:10

Angular Momentum: Single Particle

Angular momentum is directed perpendicular to the plane of the rotation, and its magnitude depends on the choice of the origin. The perpendicular vector joining the linear momentum vector of an object to the origin is called the “lever arm.” If the lever arm and linear momentum are collinear, then the magnitude of the angular momentum is zero. Therefore, in this case, the object rotates about the origin such that it lies on the rim of the circumference defined by the lever arm magnitude.
The...
Angular Momentum01:21

Angular Momentum

Angular momentum characterizes an object's rotational motion and is defined as the moment of its linear momentum about a specified point O. When a particle moves along a curved path in the x-y plane, the scalar formulation calculates the magnitude of its angular momentum, utilizing the moment arm (d), representing the perpendicular distance from point O to the line of action of the linear momentum. Despite being scalar in formulation, angular momentum is inherently a vector quantity. Its...
Angular Momentum: Rigid Body01:11

Angular Momentum: Rigid Body

The total angular momentum of a rigid body can be calculated using the summation of the angular momentum of all the tiny particles rotating in the same plane. Considering all the tiny particles rotating in the x-y plane, the direction of angular momentum of all such particles and that of the rigid body would be perpendicular to the plane of the rotation along the z-axis.
This calculation can get complicated when tiny particles within the rigid body are not rotating in the same plane but have...
Pharmacodynamic Models: Direct Effect Model and Indirect Response Model01:29

Pharmacodynamic Models: Direct Effect Model and Indirect Response Model

Pharmacodynamic models are essential tools in understanding the relationship between drug concentrations and their effects on biological systems. By characterizing the dynamics of drug action, these models guide dose selection, optimize therapeutic efficacy, and inform the development of new drugs. Two major classes of pharmacodynamic models include direct effect and indirect response models.Direct Effect ModelsDirect effect models describe the immediate relationship between drug concentration...
Transient and Steady-state Response01:24

Transient and Steady-state Response

In control systems, test signals are essential for evaluating performance under various conditions. The ramp function is effective for systems undergoing gradual changes, while the step function is suitable for assessing systems facing sudden disturbances. For systems subjected to shock inputs, the impulse function is the most appropriate test signal.
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state response.
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration01:16

IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration

A covalently bonded heteronuclear diatomic molecule can be modeled as two vibrating masses connected by a spring. The vibrational frequency of the bond can be expressed using an equation derived from Hooke's law, which describes how the force applied to stretch or compress a spring is proportional to the displacement of the spring. In this case, the atoms behave like masses, and the bond acts like a spring.
According to Hooke's law, the vibrational frequency is directly proportional to the...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Corrigendum to "Digital twins in nuclear medicine: A proposition of a modular pipeline for dosimetry protocol optimisation in molecular radiotherapy" [Comput Struct Biotechnol J (2025) 28 3287].

Computational and structural biotechnology journal·2025
Same author

Digital twins in nuclear medicine: A proposition of a modular pipeline for dosimetry protocol optimization in molecular radiotherapy.

Computational and structural biotechnology journal·2025
Same author

CT respiratory motion synthesis using joint supervised and adversarial learning.

Physics in medicine and biology·2024
Same author

Metabolic tumor volume predicts outcome in patients with advanced stage follicular lymphoma from the RELEVANCE trial.

Annals of oncology : official journal of the European Society for Medical Oncology·2023
Same author

Joint EANM/SNMMI guideline on radiomics in nuclear medicine : Jointly supported by the EANM Physics Committee and the SNMMI Physics, Instrumentation and Data Sciences Council.

European journal of nuclear medicine and molecular imaging·2022
Same author

A deep neural network for parametric image reconstruction on a large axial field-of-view PET.

European journal of nuclear medicine and molecular imaging·2022
Same journal

Effective contrast-enhanced preprocessing for intracranial artery segmentation in digital subtraction angiography.

Physics in medicine and biology·2026
Same journal

Improving Plan Quality in Adaptive Proton Therapy Using an Interactive Dose Modification Tool.

Physics in medicine and biology·2026
Same journal

Technical Note: Real-Time MLC Control and Latency Measurement Optimization with External Verification.

Physics in medicine and biology·2026
Same journal

Fetus-Specific Hematopoietic Stem Cell Dosimetry Framework for Leukemia-Relevant Target Cells During Prenatal Development.

Physics in medicine and biology·2026
Same journal

Deep learning-based dose prediction to enhance planning efficiency in cervical brachytherapy with hybrid applicators.

Physics in medicine and biology·2026
Same journal

Corrigendum: Referenceless MR thermometry-a comparison of five methods (2017<i>Phys. Med. Biol</i>.<b>62</b>1-16).

Physics in medicine and biology·2026
See all related articles

Related Experiment Video

Updated: Jun 13, 2026

Rejection of Fluorescence Background in Resonance and Spontaneous Raman Microspectroscopy
15:04

Rejection of Fluorescence Background in Resonance and Spontaneous Raman Microspectroscopy

Published on: May 18, 2011

Implementation of angular response function modeling in SPECT simulations with GATE.

P Descourt1, T Carlier, Y Du

  • 1INSERM, U650, LaTIM, IFR SclnBioS, Université de Brest, CHU Brest, Brest, F-29200, France.

Physics in Medicine and Biology
|April 16, 2010
PubMed
Summary
This summary is machine-generated.

A new method significantly speeds up SPECT simulations in medical imaging by using a tabulated collimator/detector response model within the GATE platform. This angular response function (ARF) approach reduces run times without sacrificing accuracy.

More Related Videos

Modeling Fast-scan Cyclic Voltammetry Data from Electrically Stimulated Dopamine Neurotransmission Data Using QNsim1.0
07:41

Modeling Fast-scan Cyclic Voltammetry Data from Electrically Stimulated Dopamine Neurotransmission Data Using QNsim1.0

Published on: June 5, 2017

Experimental Methods for Spin- and Angle-Resolved Photoemission Spectroscopy Combined with Polarization-Variable Laser
09:00

Experimental Methods for Spin- and Angle-Resolved Photoemission Spectroscopy Combined with Polarization-Variable Laser

Published on: June 28, 2018

Related Experiment Videos

Last Updated: Jun 13, 2026

Rejection of Fluorescence Background in Resonance and Spontaneous Raman Microspectroscopy
15:04

Rejection of Fluorescence Background in Resonance and Spontaneous Raman Microspectroscopy

Published on: May 18, 2011

Modeling Fast-scan Cyclic Voltammetry Data from Electrically Stimulated Dopamine Neurotransmission Data Using QNsim1.0
07:41

Modeling Fast-scan Cyclic Voltammetry Data from Electrically Stimulated Dopamine Neurotransmission Data Using QNsim1.0

Published on: June 5, 2017

Experimental Methods for Spin- and Angle-Resolved Photoemission Spectroscopy Combined with Polarization-Variable Laser
09:00

Experimental Methods for Spin- and Angle-Resolved Photoemission Spectroscopy Combined with Polarization-Variable Laser

Published on: June 28, 2018

Area of Science:

  • Medical Imaging
  • Computational Physics
  • Nuclear Medicine

Background:

  • The GATE simulation platform is a widely used tool for medical imaging research.
  • Standard GATE simulations for SPECT (Single-Photon Emission Computed Tomography) are accurate but computationally intensive due to photon tracking through collimators.
  • Long simulation run times limit the efficiency of SPECT research and development.

Purpose of the Study:

  • To implement a tabulated collimator/detector response model using the angular response function (ARF) within the GATE simulation framework.
  • To significantly reduce simulation times for SPECT imaging.
  • To evaluate the accuracy and performance of the ARF-based approach compared to standard GATE simulations.

Main Methods:

  • Implementation of an angular response function (ARF) model for collimator/detector response within GATE.
  • Comparison of ARF-based simulations with standard GATE simulations for SPECT.
  • Performance evaluation using a Siemens Symbia T SPECT system, a planar 364 keV source, and a realistic Jaszczak phantom with iodine-131.

Main Results:

  • The ARF-based model achieved simulation accuracy with less than 1% difference compared to standard GATE simulations.
  • Acceleration factors of up to 180 were observed for planar source simulations.
  • An acceleration factor of 100 was achieved for a complex four-head SPECT simulation of a Jaszczak phantom.

Conclusions:

  • The implemented ARF-based model for collimator/detector response in GATE significantly reduces SPECT simulation run times.
  • This method provides a substantial speed-up without compromising the accuracy of SPECT simulations.
  • The ARF approach offers a more efficient alternative for GATE-based SPECT simulations in medical imaging research.