Related Experiment Video
Updated: Jun 13, 2026

Intra-Operative Neural Monitoring of Thyroid Surgery in a Porcine Model
Published on: February 11, 2019
Systematic evaluation of the highest current threshold for regional anaesthesia in a porcine model
T Steinfeldt1, J Graf, T Vassiliou
1Department of Anaesthesiology and Intensive Care Therapy, Philipps-University Marburg, Marburg, Germany. steinfeldt@gmx.de
Background:
The purpose of this study was to determine systematically the highest minimal stimulation current threshold for regional anaesthesia in pigs.
Methods:
In an established pig model for regional anaesthesia, needle placements applying electric nerve stimulation were performed. The primary outcome was the frequency of close needle to nerve placements as assessed by resin injects and subsequent anatomical evaluation. Following a statistical model (continual reassessment method), the applied output currents were selected to limit the necessary number of punctures, while providing guidance towards the highest output current range.
Results:
Altogether 186 punctures were performed in 11 pigs. Within the range of 0.3-1.4 mA, no distant needle to nerve placement was found. In the range of 1.5-4.1 mA, 43 distant needle to nerve placements occurred. The range of 1.2-1.4 mA was the highest interval that resulted in a close needle to nerve placement rate of > or =95%.
Conclusions:
In the range of 0.3-1.4 mA, all resin deposition was found to be adjacent to nerve epineurium. The application of minimal current intensities up to 1.4 mA does not obviously lead to a reduction of epineural injectate contacts in pigs. These findings suggest that stimulation current thresholds up to 1.4 mA result in equivalent needle tip localisation in pigs.