Monitoring of cardiac output during exercise in coronary patients: a Doppler study
E Moscarelli1, B Reisenhofer, D Levantest
1C.N.R. Institute of Clinical Physiology, Pisa University, Italy.
Abstract:
The monitoring of aortic blood flow velocities by transcutaneous continuous-wave Doppler was performed in 45 patients to determine, non-invasively, the haemodynamic response to exercise in subsets of coronary patients during a multistage supine exercise tests. Group I consisted of 14 patients with ischaemia on effort (IE); group II, 12 patients with both IE and prior myocardial infarction (MI); group III, 19 patients with MI and no IE; there were also 12 normals. Peak flow velocity (PV) indices of cardiac output (CO), of peripheral resistance (PR) and of stroke work (SW) were measured every min. Resting CO was lower and PR higher in coronary patients than in normals. With exercise, for the same muscular work, CO increased less in IE patients (group I: y = 26.9 + 1.8 x cm sec-1; Group II: y = 21.9 + 1.8 x cm sec-1) than in MI (group III: y = 26.6 + 2.1 x cm s-1) and in normals (y = 35 + 2.7 x cm s-1) and PR decreased less. This suggested a more efficient distribution of CO towards working muscles. A shallower increase in SW was observed in all coronary patients in comparison with normals even if resting SW was significantly lower only in patients with MI (groups II and III). PV increased up to peak exercise only in group III, while it tended to plateau in ischaemic patients even earlier than IE occurred on the ECG.(ABSTRACT TRUNCATED AT 250 WORDS)
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...