Quantitative Analysis of Vacuum Induction Melting by Laser-induced Breakdown Spectroscopy
Published on: June 10, 2019
Utilization of the coherence function with Welch's method for signal analysis in low resolution laser-induced
Brendon O'Leary1, Jude A Kelley
1College of the Holy Cross, Worcester, Massachusetts 01610, USA.
Abstract:
This work presents a technique by which a low resolution ( approximately 1 nm) fiberoptic spectrometer may be used to definitively identify elements and molecular fragments in laser-induced breakdown spectroscopy. Commercial laser-induced breakdown spectroscopy (LIBS) spectrometers have high resolution in the area of spectral interest, and software is used to identify elements via a look-up table containing known spectral lines. When analyzing spectra from a lower resolution fiber-optic spectrometer, software based on look-up tables can produce erroneous results, reporting elements absent from the sample. As a solution to this problem, an analysis using the coherence function in conjunction with Welch's method is used to compare sample spectra with a library of reference spectra, which contain peaks primarily from a single element. The analysis has proved to be adept at identifying specific elemental signatures in multi-component samples. The technique leverages the increased information content of concomitant atomic emission lines, which are easily collected with a low resolution broadband (200-1100 nm) fiber-optic spectrometer. This technique alleviates the need for the user to visually verify the vicinity of individual peaks during testing. While Pearson's method is generally used for this type of analysis, we show that Welch's method has the advantage of being less susceptible to problems caused by continuum background.
More Related Videos
09:40Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown
Published on: February 14, 2014
08:53Dependence of Laser-induced Breakdown Spectroscopy Results on Pulse Energies and Timing Parameters Using Soil Simulants
Published on: September 23, 2013
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
UV–Vis Spectroscopy: Woodward–Fieser Rules
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.