Complete catheter disconnection and migration of an implantable venous access device: the disconnected cap sign
Walid Faraj1, Ahmad Zaghal, Ornella El-Beyrouthy
1Department of Surgery and Radiology, American University of Beirut-Medical Center, Beirut, Lebanon. wf07@aub.edu.lb
Abstract:
The use of totally implantable venous access device has provided a solution to difficult venous access. Early reports have, however, recognized several complications with their use. Catheter disruption is a rare but important complication of these devices; it may be asymptomatic but can be fatal in some cases. We present a case of a patient who had a rare and serious complication secondary to catheter disconnection from its chamber.