A dust generator for laboratory use.

V A Marple, B Y Liu, K L Rubow

    American Industrial Hygiene Association Journal
    |January 1, 1978
    PubMed
    Summary
    This summary is machine-generated.

    A novel dust generator creates dry dust aerosols from various powders for instrument calibration. This device deagglomerates and aerosolizes particles in a fluidized bed for laboratory studies.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    [Effectiveness and safety of atezolizumab plus bevacizumab versus lenvatinib in patients with unresectable HBV-related hepatocellular carcinoma].

    Zhonghua yi xue za zhi·2026
    Same author

    [Application and research progress of artificial intelligence in the diagnosis and treatment of rare lung diseases].

    Zhonghua jie he he hu xi za zhi = Zhonghua jiehe he huxi zazhi = Chinese journal of tuberculosis and respiratory diseases·2026
    Same author

    [PRRX1-rearranged fibroblastic tumor: report of a case].

    Zhonghua bing li xue za zhi = Chinese journal of pathology·2025
    Same author

    [Primary malignant perivascular epithelioid cell tumors with TFE3 rearrangement of bone: a clinicopathological analysis of two cases].

    Zhonghua bing li xue za zhi = Chinese journal of pathology·2024
    Same author

    [The role of NLRP3 inflammasome pathway in silicosis-induced pulmonary fibrosis and its prospect as a therapeutic target].

    Zhonghua lao dong wei sheng zhi ye bing za zhi = Zhonghua laodong weisheng zhiyebing zazhi = Chinese journal of industrial hygiene and occupational diseases·2024
    Same author

    [Evaluation effect of COMPERA 2.0 risk assessment model on prognosis of Chinese patients with pulmonary arterial hypertension].

    Zhonghua yi xue za zhi·2023
    Same journal

    Barrier durability of latex and vinyl medical gloves in clinical settings.

    American Industrial Hygiene Association journal·2001
    Same journal

    Microwave emissions from police radar.

    American Industrial Hygiene Association journal·2000
    Same journal

    Assessment of magnetic field exposures for a mortality study at a uranium enrichment plant.

    American Industrial Hygiene Association journal·2000
    Same journal

    An assessment of occupational noise exposures in four construction trades.

    American Industrial Hygiene Association journal·2000
    Same journal

    Prediction of rectal temperature by the Questemp II personal heat strain monitor under low and moderate heat stress.

    American Industrial Hygiene Association journal·2000
    Same journal

    Indoor airborne fiber levels of MMVF in residential and commercial buildings.

    American Industrial Hygiene Association journal·2000
    See all related articles

    Area of Science:

    • Engineering
    • Environmental Science
    • Material Science

    Background:

    • Accurate calibration of aerosol measurement instruments is crucial for environmental monitoring and laboratory research.
    • Existing methods for generating dry dust aerosols can be limited in control and material versatility.

    Purpose of the Study:

    • To develop and present a new dust generator capable of producing dry dust aerosols from diverse powderous materials.
    • To enable reliable instrument calibration and facilitate laboratory studies involving particulate matter.

    Main Methods:

    • A chain conveyor feeds powder at a controlled rate into a fluidized bed.
    • Fluidization deagglomerates and aerosolizes particles.
    • Adjustable powder feed rates (1.2-36 mm³/min) and air flow rates (9-30 Lpm) allow for controlled aerosol generation.

    Related Experiment Videos

    Main Results:

    • Successfully generated aerosols from coal, silica, potash, rock, and Arizona road dust.
    • The generated dust aerosols were suitable for calibrating optical particle counters and aerosol mass monitors.
    • The dust generator demonstrated consistent performance across various materials and operational parameters.

    Conclusions:

    • The developed dust generator provides a versatile and controllable method for producing dry dust aerosols.
    • This instrument is effective for calibrating critical aerosol monitoring equipment.
    • The technology supports advancements in aerosol science and environmental instrumentation.